JCM Part No. 960-000076R_Rev. 1
© 2007, JCM-American Corporation
A - 9
Troubleshooting
World Bill Acceptor (WBA®-1x/2x -SS & SS2)
Appendix A
Bill Acceptance Test
There are two ways to run the Bill Acceptance
Test:
1. With a separate head and transport.
• The Cash Box Sensor (S2) and Stacker Home
Sensor (S1) are disabled and not tested.
2. With a head and transport inserted into a frame
containing a Cash Box.
• All sensors and functions are tested.
Bill Acceptance Test Modes
To Enter a Bill Acceptance mode:
1. Turn DIP Switch No. 8
“ON”
, apply power
(diagnostic mode) and:
• Turn the related DIP Switches ON according
to the Table A-8 chart settings
–
The unit will cycle and be ready to accept
and identify bills.
Bill Identification in Bill Acceptance
• Bill identification is done by counting the LED
flashes after a bill is validated as follows:
–
1 flash = $1
–
2 flashes = $2 (not programmed)
–
3 flashes = $5
–
4 flashes = $10
–
5 flashes = $20
–
6 flashes = $50
–
7 flashes = $100
–
8 flashes = Bar Code Ticket.
Forced Download Mode
Perform the following steps to initiate a Forced
Download:
1. Select the appropriate download speed (see the
Table A-9 Chart).
2. Connect the WBA-1X per the download tool
requirement.
3. Power up the WBA-1X.
DT-004 Downloading
Perform the following steps to initiate a DT-004
Download:
1. Connect the DT-004 (Part No. 501-000022R)
to the PS15-006 power supply (Part No.
550-100042R).
• Or at game use adapter harness (Part No.
400-100068R for a WBA 10 or Part No.
400-100069R for a WBA 12).
2. Install the appropriate master EPROM chip into
the DT-004.
Table A-8
WBA-1X/2X Bill Acceptance Test Setting Chart
DIP Switch Positions
Bill Acceptance Test Activated
8
7
6
5
4
3
2
1
E/D
*
X
X
X
†
Bill Acceptance Test without Cash Box and Frame
E/D
X
X
X
X Bill Acceptance Test with Cash Box and Frame
*. E/D = Enable/Disable
†. X = ON
Table A-8 provides the DIP Switch settings for performing the WBA-1X/2X Bill Acceptance Tests.
NOTE: Switch #1 needs to be turned OFF after
the Bill Acceptance Test has started to enable
Bar Code ticket reading (ID003 Software).
NOTE: For multiple WBA-1X downloads,
refer to the Multi-Download Adapter Kit
Users Manual. (Part No. 701-000031R).
Table A-9
WBA-1X/2X Forced Download Mode Chart
DIP Switch Positions
Download Speed Selected
8
7
6
5
4
3
2
1
X
*
X
9,600 Baud - WBA 10 or WBA 12/14
X
X
X
19,200 Baud - WBA 10 or WBA 12/14
X
X
X
X
38,400 Baud - WBA 12/14
*.X = ON
Table A-9 provides the DIP Switch settings for performing various WBA-1X/2X Forced Download
NOTE: The default speed for downloading