P/N 960-100175R_Rev. 4 {EDP #200824}
© 2013, Japan CashMachine Co., Limited
6 - 8
Section 6
Taiko™ Series Banknote Acceptor Calibration
and
Testing
In order to identify a failure condition’s cause, the
Taiko™ Unit has to be in the TEST Mode.
The various Taiko™ Tests available and their
related DIP Switch settings are listed in Table 6-2.
DIP S
WITCH
T
ESTS
Prior to entering the Test Mode, perform the
following steps to test the DIP Switch Functions:
1. Set all DIP Switches to their
ON
position and
supply Power to the Taiko™ Unit.
2. Set DIP Switch No.1 to
OFF
to begin the Test.
The Front Panel LED will light a steady
Yellow
Color.
3. Set DIP Switches No. 1, 5 and 7 to
OFF
, and
verify that the Front Panel LED lights
Green
.
4. Now, set DIP Switches No. 2, 4, 6 and 8 to
OFF
,
and verify that the Front Panel LED lights
Blue
.
No.1 Transport Motor Forward Rotation Test
This Test detects the Taiko™ Units forward Motor
speed rotational rate. Confirm that the Motor oper-
ates smoothly without emitting abnormal noise.
1. Set DIP Switch No.1 to
ON
and supply power to
the Taiko™ Unit.
2. Set DIP Switch No.1 to
OFF
to begin the Test.
The Transport Motor will rotate in a forward
direction. The
Blue
Front Panel LED will flash,
and despite the number of flashes, the Test is
complete when no error is detected.
No.2 Transport Motor Reverse Rotation Test
This Test detects the Taiko™ Unit’s reverse Motor
speed rotational rate. Confirm that the Motor oper-
ates smoothly without emitting abnormal noise.
1. Set DIP Switch No.1 and No.2
ON
and supply
power to the Taiko™ Unit.
2. Set DIP Switch No.1 to
OFF
to begin the Test.
The Transport Motor will rotate in a reverse
direction. The
Blue
Front Panel LED will flash,
and despite the number of flashes, the Test is
complete when no error is detected.
No.3 Aging Test Procedure
This Test detects component aging within the
Taiko™ Unit. Proceed as follows to perform the
Aging Test:
1. Set DIP Switches No. 1, 2 and 4
ON
and supply
the Power to the Taiko™ Unit.
2. Set DIP Switch No.1 to
OFF
to begin the Test.
The Taiko™ Unit will begin repeating the fol-
lowing operation continuously:
–
The Motor rotates forward, then
–
The Motor rotates in reverse.
A
Blue
Front Panel Color indicates proper
operation.
If a Sensor error occurs during an Aging Test, the
Taiko™ will stop operating. The Sensor exhibit-
ing the error can be determined by counting the
number of
Red
LED flashes and comparing the
count to the list in the first part of Table 6-3.
Table 6-2
Taiko TEST DIP Switch Settings
Setting Function SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8
DIP Switch Test ON ON ON ON ON ON ON ON
Transport Motor
Forward
Rotation Test
ON OFF OFF OFF OFF OFF OFF OFF
Transport Motor
Reverse
Rotation Test
ON ON OFF OFF OFF OFF OFF OFF
Aging Test
ON ON OFF ON OFF OFF OFF OFF
Solenoid Test
ON ON ON ON OFF OFF OFF OFF
Acceptance
Test
ON OFF OFF OFF ON OFF OFF OFF
Entrance
Flapper Test
ON OFF OFF ON ON OFF OFF OFF
Exit Flapper
Test
ON ON OFF ON ON OFF OFF OFF
ON
WARNING: If the
Red
LED lights, the DIP
Switch Block is faulty.
WARNING: If the
Red
LED lights, the DIP
Switch Block is faulty.
Table 6-3
Aging Test Error Codes
Flash No.
& Color
Sensor Location
1
Right Entrance Sensor
2
Left Entrance Sensor
3
Upper Transit Sensor
4
Lower Transit Sensor
5
Entrance Solenoid Sensor
6
Exit Solenoid Sensor
7
VEND Lever Sensor
8
Encoder Sensor
1
Right IR Transmissive (Upper to Lower)
2
Left IR Transmissive (Upper to Lower)
3
Right Red Transmissive (Upper to Lower)
4
Left Red Transmissive (Upper to Lower)
5
Right NIR Transmissive (Upper to Lower)
6
Left NIR Transmissive (Upper to Lower)
7
Right Blue Transmissive (Upper to Lower)
8
Left Blue Transmissive (Upper to Lower)
1
Right IR Transmissive (Upper to Lower)
2
Left IR Transmissive (Upper to Lower)
WARNING: If the
Red
LED lights, the DIP
Switch Block is faulty.