9. Open the Upper Lid by pressing-in and holding
down the Upper Lid Open/Close Buttons while
lifting the Lid up (See Figure 2-6
).
10. Insert the Bezel Installation Guide Pin into the
Bezel Guide (See Figure 2-6
).
11. Slide the Guide all the way in and push down on
the Taiko™ Unit body (See Figure 2-6
).
12. Close the Upper Lid firmly until a locking Click
is heard (See Figure 2-7).
Power Harness Wiring Procedure
Before beginning to build a Power Interface
Connector, ensure one of the two plug types listed
Once the Power Interface Connector Plug has been
fastened to the Power/Signal Cable being used,
perform the following steps:
1. Confirm the power is NOT supplied to the new
Power Harness.
2. Insert the new Power Harness Socket into the
right side Panel Interface Connector of the
Taiko™ Unit Body (See Figure 2-8).
3. Supply power and confirm that the Taiko™ Unit
operates properly.
Clearing a Banknote Jam
Clearing an Upper Area Banknote Jam
When an upper area Banknote jam occurs, the
Front Panel
Red
LED Display will begin blinking
three (3) time with a pause between blink sets.
Perform the following steps to clear a Banknote
jam within the Taiko™ Unit’s Acceptor area:
1. Remove Power from the Taiko™ Unit.
Figure 2-5
Mounting the Taiko Bezel
Bezel Brackets
Hexagonal
Nuts
Figure 2-6
Installing the Taiko Bezel
Figure 2-7
Closing the Taiko Upper Lid
Click
Caution: Ensure that the Taiko Unit body
and Bezel are firmly installed and stably
fixed to the door before closing the
Upper Lid; When closing the Upper Lid,
be careful not to get your finger caught
under the lid when pressing it closed.
NOTE: When removing a Taiko Unit, perform the
reverse procedure as previously described.
Table 2-1
Power Connector Specifications
Part
Connector
Lock Lever Socket
Ribbon Cable Socket
Plug
XG5M-1032-N
(Omron)
XG4M-1030-T
(Omron)
Semi-Cover
XG5X-0501 (Omron)
N/A
Lock Lever 2 XG4Z-0002 (Omron)
N/A
Applicable
Wire Size
UL1061 WAG24
1.27mm Pitch Flat
Ribbon Cable, AWG28
UL2651 or UL20012
NOTE: DIP Switch settings may vary based on
Software changes related to the specific Country
using the Taiko Unit.
Figure 2-8
Attaching a Taiko Power Connector
WARNING: When installing a Taiko Unit,
or connecting its Harness Plug, be sure
power to the harness is disconnected.
The Taiko Unit is only designed to use a
12 Volt DC input. Any other power level
can damage the Taiko Unit!
If the power Harness itself is strongly
pulled on, it may tear loose from its
Connector’s Pins.