P/N 960-000164R_Rev. 3 {EDP #213631}
© 2018, JAPAN CASH MACHINE CO., LTD.
6 - 3
Performance Tests
iPRO-RC™ Series Banknote Recycler
Section 6
JCM Tool Suite Standard Edition
When the “
JCM Tool Suite Standard Edition
” is
installed, the Short-cut Icon shown in Figure 6-10
will appear on the PC Desktop.
To activate the “
JCM Tool Suite Standard Edi-
tion
” Software Program, Double-Click on the
Short-cut Icon. The “
JCM Tool Suite Standard
Edition
” Screen shown in Figure 6-11 will appear
on the PC Monitor.
The
Device Information
Text Fields shown in
list the Model Information when
the Device is connected to a PC.
The
Service Mode
Pull-down Menu shown in
b
contains several functional selections.
The selection items will appear depending on the
specific DIP Switches set to create them
.
Firmware Download Procedure
To download the iPRO-RC™ Firmware, proceed as
follows:
1. Copy the iPRO-RC™ Firmware File and paste it
on the PC Desktop. (Review Figure 6-1 “Tool and
Harness Connection” on page 6-1 to properly
select and set-up the Cable connections).
2. Turn the iPRO-RC™ Power Supply
OFF
.
3. Set the iPRO™ Transport Unit’s 8-Position DIP
Switches #6, #7 and #8 to
ON
a
).
4. Connect the iPRO-RC™ and the PC together
using the recommended USB Cable.
5. Turn the iPRO-RC™ Power Supply
ON
. The
iPRO™ Transport Unit LED will begin alter-
nately flashing at a
Green
and
Red
Color Rate,
and the iPRO-RC™ Status will revert to Stand-by
Mode.
6. Launch the “
JCMToolSuiteStandardEdition.exe
”
Program.
7. When
the
“
JCM Tool Suite Standard Edition
”
Screen shown in Figure 6-14 appears, click on the
Service Mode Pull-down Menu and select “
Down-
load
” (Figure 6-14
a
).
8. The
“
JCM Downloader Suite Edition Ver X.XX
”
Program will activate automatically.
9. When
the
communication line between the
iPRO-RC™ and the PC is connected, “
Online
”
will appear in
Green
Text (Figure 6-16
a
) below
the Download Screen Button.
click on the “
Browse
”
Screen
Button (Figure 6-16
b
).
Figure 6-10
Figure 6-10
JCM Tool Suite Short-cut Icon
Figure 6-11
JCM Tool Suite Standard Edition
Figure 6-11
JCM Tool Suite Standard Edition
a
b
NOTE: Service Mode Pull-down Menu listings will depend on
DIP Switch Setting selections.
Figure 6-12
Figure 6-12
iPRO-RC DIP Switch Setting
Figure 6-13
Figure 6-13
DIP Switch Location
a
Figure 6-14
Select Download
a
NOTE: When the download program
is activated for the first time, an
“Invalid File!” message pop-up
Dialog Box (Figure 6-15) will appear
because the Firmware File has not
yet been selected. Click on the
Dialog’s “
OK
” Screen Button (Figure
a
), and select the proper
Firmware File. Once the Firmware
File is selected, the message will no
longer appear again.
Figure 6-15
Figure 6-15
Invalid File! Dialog Pop-Up Screen