P/N 960-100189R_Rev. 4 {EDP #148850}
© 2016, JAPAN CASH MACHINE CO., LTD.
6 - 1 8
Section 6
VEGA™ Series Banknote Validator Calibration
and
Testing
2. Set DIP Switch DS1 Switch #1 to
ON
as indicated
in Table 6-2 for this Test.
3. Turn the VEGA Unit power
ON
.
4. Set DIP Switch DS1 Switch #1 to
OFF
. When the
Feed Motor Forward Rotation Test begins, the
Front Panel LED will extinguish.
If the Feed Motor correctly rotates in a forward
direction, the Front Panel LED will be extin-
guished and forward rotation will continue.
5. To end the forward Feed Motor Test, turn the
VEGA Unit power
OFF
, or set DIP Switch DS1
Switch #1 to
ON
.
F
EED
M
OTOR
R
EVERSE
R
OTATION
T
EST
Perform the following steps to test the normal
reverse rotation functionality of the Feed Motor:
1. Ensure that the VEGA Unit power is
OFF
.
2. Set DIP Switch DS1 Switch #1 and #2 to
ON
as
indicated in Table 6-2 for this Test.
3. Turn the VEGA Unit power
ON
.
4. Set DIP Switch DS1 Switch #1 to
OFF
. When the
Feed Motor reverse rotation test begins, the Front
Panel LED will extinguish.
If the Feed Motor rotates in reverse correctly, the
Front Panel LED will be extinguished and reverse
rotation will continue.
5. To end the reverse Feed Motor Test, turn the
VEGA Unit power
OFF
, or set DIP Switch DS1
Switch #1 to
ON
.
S
TACKER
M
OTOR
T
EST
Perform the following steps to test the Stacker
Motor rotation functionality:
1. Ensure that the VEGA Unit power is
OFF
.
2. Set DIP Switch DS1 Switch #1 and #3 to
ON
as
indicated in Table 6-2 for this Test.
3. Turn the VEGA Unit power
ON
.
4. Set DIP Switch DS1 Switch #1
OFF
. When the
Stacker Motor Test begins, the Front Panel LED
will extinguish.
5. If the Stacker Motor rotates forward/reverse cor-
rectly, the Front Panel LED will be extinguished,
and the Motor will continue operating in a for-
ward/reverse direction.
6. To end the Stacker Motor Test, turn the VEGA
Unit power
OFF
, or Set DIP Switch DS1 Switch
#1 to
ON
.
A
GING
T
EST
The Aging Test repeatedly performs basic Validator
functions such as feeding, transporting and stacking
operations.
Perform the following steps to repeatedly test the
VEGA Unit’s basic feeding, transporting and stack-
ing functional performance:
1. Ensure that the VEGA Unit power is
OFF
.
2. Set DIP Switch DS1 Switch #1, #2 and #4 to
ON
as indicated in Table 6-2 for this Test.
3. Turn the VEGA Unit power
ON
.
4. Set DIP Switch DS1 Switch #1 to
OFF
. When the
Aging Test begins, the Front Panel LED will
extinguish. If operation is normal, the Unit will
perform the following five (5) functions repeti-
tively until the test is stopped:
a) Feed Motor Reverse Rotation Test
b) Interval Test (20sec, LED lights White)
c) Feed Motor Forward Rotation Test
d) Stacking Test
e) Interval Test (20sec, LED lights White)
5. To end the Aging Test, turn the VEGA Unit
power OFF, or set DIP Switch DS1 Switch #1
ON
.
Table 6-3
Feed Motor Abnormal Error Codes
Flash
Sequence
Error Description
3 times
Feed Motor Low Speed Problem
5 times
Feed Motor High Speed Problem
7 times
Feed Motor Lock-up Problem
NOTE: If the Front Panel LED
flashes any White Error sequence
indicated in Table 6-3, the Feed
Motor forward rotation is abnormal.
NOTE: If the Front Panel LED
flashes any error sequence indicated
in Table 6-3, the Feed Motor’s
reverse rotation is abnormal.
Table 6-4
Stacker Motor Abnormal Error Codes
LED
Color
Flash
Sequence
Error Description
Red
5 times
Cash Box Seating Problem
Purple
5 times
Stacker Motor Lock-up
7 times
Stacker Motor Gear Problem
Orange
3 times
Stacker Full
Table 6-5
Feeding/Stacking Abnormal Error Codes
LED
Color
Flash
Sequence
Error Description
White
3 times
Feed Motor Low Speed Problem
5 times
Feed Motor High Speed Problem
7 times
Feed Motor Lock-up
Red
5 times
Cash Box Seating Problem
Purple
5 times
Stacker Motor Lock-up
7 times
Stacker Motor Gear Problem
NOTE: If the Front Panel LED
flashes any error sequence indicated
in Table 6-4, the Stacker Motor’s
reverse rotation is abnormal.
NOTE: If the Front Panel LED
flashes any error sequence indicated
in Table 6-5, the Feeding and/or
Stacking function is abnormal.