Lecture Notes
Error and Reject Code Tables (Continued)
Table 11 lists the various VEGA Reject Code LED combinations.
Table 11
LED Reject Codes
On-Line
Off-Line
Error
Possible Cause
Color Flashes
(mSec)
Color Flashes
(mSec)
Yellow 3 (120)
White 3 (300)
Transport Slip
Sensor does NOT detect Banknote even though the number of Banknotes
transported is more that the accepted value.
Yellow 3 (120)\
Red ON
Transport Time-out
Sensors do NOT detect movement even though Banknote transport time is longer
than acceptable.
Yellow ON
Red 3 (120)\
Yellow 3 (120)\
Blue ON
Transport Motor Lock-up
While the Feed Motor is operating, no pulse inputs exist greater than the rated
value.
Yellow ON
Blue 3 (120)
Yellow 3 (120)\
Green ON
Transport Speed High
While performing the transportation process, pulse interaction was shorter than the
accepted value.
Purple ON
Green 3 (120)
Yellow 3 (120)
Red 3 (120\
Abnormal Timing Response
Sensor detected a Banknote remaining in path or none present during an abnormal
timing interval.
Yellow 3 (120)\
Yellow ON
Side Sensor Problem
Side Sensor detected a Banknote before it passed through Guide Sensor and after
it passed the Side Sensor.
White ON
Yellow 3 (120)