© 2013, JCM American, Corporation
1 8
Lecture Notes
July, 2013
NON-PC CALIBRATION PROCEDURES
When removing or replacing the Sensor, Sub-Sensor, or CPU Board, perform
the following steps to calibrate the Entrance, Validation, and Edge Sensors of
the VEGA Unit.
1. Figure 11 illustrates the Calibra-
tion connection Tools and Har-
ness configurations necessary
when calibrating WITHOUT
using a PC.
2. Set DS 1, Switches #1, #2, & #8
to ON. Ensure ALL DS 2
Switches are OFF.
3. Apply power to the VEGA and
the Front Panel LED will blink
Green
.
4. Set DS 1, Switch #1 OFF.
5. The Front Panel LED will now
slowly blink at a
Cyan
Color
rate.
6. Set DS 2, Switch #1 ON.
This action begins the Entrance Sensor's Adjustment Procedure without
Reference Paper in Place.
7. The Front Panel LED will slowly blink at a White Color Rate once the Entrance
Sensor's adjustment is complete.
NOTE: If any of the Sensors are dirty the calibration will not be
accurate. Be sure to clean all the Sensors before calibrating
the Unit.
NOTE: There are two types of Calibration Procedures:
• Calibration using a PC, and
• Calibration without using a PC.
To calibrate using a PC, refer to the VEGA Operation and
Maintenance Manual, Section 6, Page 6-6.
Figure 11
Non-PC Calibration Tools
and Cabling
a
e
d
b
Interface Connector
Power Supply
To AC
Receptacle
Power
c
a) VEGA Unit
b) Power Supply (e.g., UAC, VM-VEGA, etc.)
c) Harness
d) White Reference Paper KS-325 (Part#
190876)
e) Black Reference Paper KS-326 (Part #
190875).
NOTE: Do not touch the
VEGA Unit while it's adjusting.
NOTE: Keep DS 2 Switches ON until instructed to turn them OFF.