© 2020, JAPAN CASH MACHINE CO., LTD.
6 - 2 5
Calibration and Testing
UBA Pro RT/RQ™ Series Banknote Recycler
Section 6
Drum 2 Motor Test (RT Transport)
To run the Recycler Solenoid on the RT Transport
side, proceed as follows:
1. Remove electrical power.
2. Set the DIP Switches of the UBA Pro Unit as
below (Figure 6-125).
3. Set the DIP Switches of the RT/RQ Unit as below
4. Apply electrical power.
5. Confirm that the Status LED/Collect Button is lit
at
Green
Color and then turns off.
6. To start the Test, set the UBA Pro DIP Switch #8
to
OFF
7. The Drum 2 of the Recycler will start winding
the Tape until it reaches to “End” and then to
“Full” position back and forward repeatedly.
8. Set the UBA Pro DIP Switch #8 to
ON
to end the
test.
RQ Transport Performance Tests
This section provides instructions for conducting a
Performance Test Without a PC on the RQ Trans-
port side (Figure 6-71
b
).
Feed Motor Normal Rotation Test
(RQ Transport)
To run the Feed Motor Normal Rotation Test on the
RQ Transport side, proceed as follows:
1. Remove electrical power.
2. Set the DIP Switches of the UBA Pro Unit as
3. Set the DIP Switches of the RQ Unit as below
4. Apply electrical power.
5. Confirm that the Status LED/Collect Button is lit
at
Green
Color and then turns off.
Figure 6-127
Figure 6-127
Drum 2 Motor Test (RT Transport) 1
DIP Switches #1, #2, #6, #8 ON
ON
1
2
3
4
5
6
7
8
Figure 6-128
Figure 6-128
Drum 2 Motor Test (RT Transport) 2
DIP Switch #7 ON
ON
1
2
3
4
5
6
7
8
NOTE: Wait for the Status LED to turn off
in order to run the test properly.
Figure 6-129
Figure 6-129
Drum 2 Motor Test (RT Transport) 3
Green
ON
OFF
Figure 6-130
Figure 6-130
Drum 2 Motor Test (RT Transport) 4
DIP Switch #8 OFF
ON
1
2
3
4
5
6
7
8
Figure 6-131
Feed Motor Normal Rotation Test
(RQ Transport) 1
DIP Switches #1, #2, #6, #8 ON
ON
1
2
3
4
5
6
7
8
Figure 6-132
Feed Motor Normal Rotation Test
(RQ Transport) 2
DIP Switches #1, #8 ON
ON
1
2
3
4
5
6
7
8
NOTE: Wait for the Status LED to turn off
in order to run the test properly.
Figure 6-133
Figure 6-133
Feed Motor Normal Rotation Test
(RQ Transport) 3
Green
ON
OFF
Содержание UBA Pro RT Series