Preservation and Storage
Storage
45
9831/3200-3
45
Preservation and Storage
Storage
General
(For: Lead Acid Battery)
A long period of inactivity can be extremely harmful to lead acid batteries. When placing a battery into storage,
follow the procedure below to ensure that the battery remains healthy and ready for use.
You can store, charge or operate the batteries on a concrete floor.
Avoid locations where freezing temperature are expected. Keeping a battery at a high state of charge will also
prevent freezing. Freezing results in irreparable damage to the battery's plates and container.
Avoid direct exposure to heat sources, such as radiators or heaters. Temperatures above 26.6°C (79.8°F)
accelerate the battery's self discharge characteristics.
Storage Procedure
1. Completely charge the battery before storing.
2. Store the battery in cool, dry location, and protected from the elements.
3. During storage monitor the specific gravity (flooded) or voltage. Batteries in storage should give a boost
charge when they show a 70% charge or less.
4. Completely charge the battery before re-activating.
5. For optimum performance, equalise the batteries (flooded) before putting them back into service.
(For: Lithium Iron Phosphate Battery)
When storing the machine for prolonged periods, keep the batteries installed in the machine.
Storage Procedure
1. Completely charge the battery before storing the machine.
2. Store the machine in a cool, dry location and protect from the elements.
3. If possible, store the machine with AC (Alternating Current) power connected.
4. If not stored connected to AC power, then connect AC power so that the batteries can charge for 48hrs
before use.
Take out of Storage
After long-term storage, it is recommended to service the machine before operation. For more information
contact your JCB dealer.
Содержание S1530E
Страница 2: ......
Страница 4: ...9831 3200 3 Notes...
Страница 16: ...About the Product Description 8 9831 3200 3 8 Y Charging plug Z Power to platform plug...
Страница 29: ...Operation Entering and Leaving the Operator Station 21 9831 3200 3 21 Figure 12 A A Lever...
Страница 31: ...Operation Battery Isolator 23 9831 3200 3 23 Figure 14 Lithium Iron Phosphate Battery A A Battery isolator...
Страница 35: ...Operation Slopes 27 9831 3200 3 27 Figure 16 B A A Front back slope B Side slope...
Страница 52: ...Notes 44 9831 3200 3 44...
Страница 54: ...Notes 46 9831 3200 3 46...
Страница 75: ...Maintenance Safety Equipment 67 9831 3200 3 67 Figure 41 A A Tilt sensor...
Страница 90: ...Notes 82 9831 3200 3 82...
Страница 119: ...Technical Data Warranty Information 111 9831 3200 3 111 Figure 76 11000h 132 Month h...
Страница 120: ...Notes 112 9831 3200 3 112...