WARNING! Read all safety 
warnings and all instructions.

 

Failure to follow the warnings and 
instructions may result in electric 
shock, fire and/or serious injury.

Save all warnings and instructions 
for future reference.

The term "power tool" in the 
warnings refers to your electric 
(corded) power tool or battery-
operated (cordless) power tool.

1. Work area safety

a)  Keep work area clean and well 
lit. 

Cluttered or dark areas invite 

accidents.

b)  Do not operate power tools in 
explosive atmospheres, such as in 
the presence of flammable liquids, 
gases or dust. 

Power tools create 

sparks which may ignite the dust 
or fumes.

c)  Keep children and bystanders 
away while operating a power tool. 

Distractions can cause you to 
lose control.

2. Electrical safety

a)  Power tool plugs must match 
the outlet. Never modify the plug 
in any way. Do not use any adapter 
plugs with grounded power tools. 

Unmodified plugs and matching 
outlets will reduce risk of electric 
shock.

b)  Avoid body contact with 
grounded surfaces, such as pipes, 
radiators, ranges and refrigerators. 

There is an increased risk of 
electric shock if your body is 
grounded.

c)  Do not expose power tools 
to rain or wet conditions. 

Water 

entering a power tool will increase 
the risk of electric shock.

d)  Do not abuse the cord. Never 
use the cord for carrying, pulling 
or unplugging the power tool. 
Keep cord away from heat, oil, 
sharp edges or moving parts. 

Damaged or entangled cords 
increase the risk of electric shock.

e)  When operating a power tool 
outdoors, use an extension cord 
suitable for outdoor use. 

Use of 

a cord suitable for outdoor use 
reduces the risk of electric shock. 

f)  If operating a power tool in a 
damp location is unavoidable, use 
a residual current device (RCD) 
protected supply. 

Use of an RCD 

reduces the risk of electric shock. 

3. Personal safety

a)  Stay alert, watch what you are 
doing and use common sense 
when operating a power tool. Do 
not use a power tool while you 
are tired or under the influence 
of drugs, alcohol or medication. 

A moment of inattention while 

GENERAL POWER TOOL SAFETY WARNINGS

ORIGINAL INSTRUCTIONS

Содержание JCB-SDS780

Страница 1: ...JCB SO53 3LE www JCBDIY com Customer Helpline 0333 0143092 Safety and operating manual SDS Plus Hammer JCB SDS780...

Страница 2: ......

Страница 3: ...lets will reduce risk of electric shock b Avoid body contact with grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is ground...

Страница 4: ...ose clothes jewellery or long hair can be caught in moving parts g If devices are provided for the connection of dust extraction and collection facilities ensure these are connected and properly used...

Страница 5: ...s different from those intended could result in a hazardous situation 5 Service a Have your power tool serviced by a qualified repair person using only identical replacement parts This will ensure tha...

Страница 6: ...run the machine with any part of the casing missing or damaged 7 Use a detector to localize lines in walls with concealed electric water or gas lines Avoid touching live components or conductors 8 Bef...

Страница 7: ...elating to removing electric and electronic waste This means that this product shall not be discarded with household waste but that it shall be returned to a collection system which conforms to the Eu...

Страница 8: ...K ON BUTTON 3 FORWARD AND REVERSE ROTATION CONTROL 4 FUNCTION MODE SELECTION SWITCH 5 AUXILIARY HANDLE 6 ADJUSTABLE DEPTH STOP 7 TOOL HOLDER LOCKING SLEEVE 8 DUST PROTECTION CAP 9 SDS PLUS TYPE CHUCK...

Страница 9: ...RATION INFORMATION Vibration total values triax cover sum determined according to EN60745 Hammer drilling into concrete Vibration emission value a h HD 14 060m s2 Uncertainty K 1 5m s Chiselling a h C...

Страница 10: ...the tool is switched off and when it is running idle but not actually doing the job This may significantly reduce the exposure level over the total working period Help to minimize your vibration expo...

Страница 11: ...e Drill Chuck To work with tools without SDS plus e g drills with cylindrical shafts a suitable drill chuck must be used Insert the adapter 11 of the drill chuck 10 with a twisting motion into the SDS...

Страница 12: ...erior quality SDS bits to break and jam in the chuck We therefore recommend that only high quality SDS bits be used with this tool 3 MOUNTING OF BIT IN KEYED CHUCK WARNING Do not use tools without SDS...

Страница 13: ...ff switch first and the lock on button second Your switch is now locked on for continuous use To switch off your tool just depress and release the on off switch 6 AUXILIARY HANDLE Slide the handle ont...

Страница 14: ...you wish to make Then clamp the depth stop by rotating the handle clockwise 9 FUNCTION MODE SELECTION See D The operation of the gearbox for each application is set with the function mode selection s...

Страница 15: ...LE www JCBDIY com Customer Helpline 0333 0143092 Warning The operating mode selector switch may be actuated only at a standstill Warning Prolonged use will cause the aluminum housing to become hot do...

Страница 16: ...ry place Keep the motor ventilation slots clean Keep all working controls free of dust Occasionally you may see sparks through the ventilation slots This is normal and will not damage your power tool...