21 - 3
Battery Isolator
To disconnect the battery from the machine electrics a
battery isolator has been fitted.
!
CAUTION
Except in an emergency, do not use the battery isolator
to switch OFF the engine. Failure to comply may result in
damage to the electrical circuits.
INT-3-2-13
At the end of a working cycle or if the machine is being left
unattended, provided the lights are not required, the battery
must be isolated. Before attempting to start the engine or
use the machine electrics the battery isolator key must be
fitted and switched on.
1
To isolate the battery turn the battery isolator key
A
in
an anti-clockwise direction
B
and remove. Keep the key
in a safe place and available for when the machine is
next required.
2
To connect the battery insert the key
A
and turn in a
clockwise direction
C
.
!
CAUTION
Before carrying out arc welding on the machine
disconnect the battery and alternator to protect the
circuits and components.
The battery must still be disconnected even if the battery
isolator is fitted.
INT-3-1-13
Section 3
9803/3280
Section 3
21 - 3
Issue 1
Battery
A323611
B
C
A