Gateway 900 Installation Manual 

 

Page 15 

 
 
 
 

UK 

 

ƒ

  The supply plug must comply with BS1363 (3-pin 13-amp) and be fitted with a 5 A fuse which compiles with 

BS1362.

 

ƒ

  The main cords must be <HAR> or <BASEC> marked and be of type HO3VVF3G0.75 (minimum).

 

 

Europe 

 

ƒ

 

The supply plug must comply with CEE7/7 (“SCHUKO”) 

ƒ

 

The main cords must be <HAR> or <BASEC> marked and be of type HO3VVF3G0.75 (minimum). 

 
 

L’INFORMATION DE SÉCURITÉ IMPORTANTE 

Veuillez lire à fond l’information de la sécurité suivante avant d’installer le Baseline Dual Speed Hub. 
 
Avertissement: L’installation et la dépose de ce groupe doivent être confiés à un personnel qualifié. 
 

ƒ

 

Ne branchez pas votre appaireil sur une prise secteur (alimentation électrique) lorsqu’il n’y a pas de 
connexion de mise à la terre (mise à la masse). 

ƒ

 

Vous devez raccorder ce groupe à la terre (mise à la masse) afin de respecter les normes internationales 
de sécurité. 

ƒ

 

Le coupleur d’appareil (le connecteur du goupe et non pas la prise murale) doit repecter une configuration 
qui permet un branchement sur une entrée d’appareil EN60320/IEC 320. 

ƒ

 

La prise secteur doit se trouver  à proximité de l’appareil et son accès doit être facile.  Vous ne pouvez 
mettre l’appareil hors circuit qu’en dèbranchant son cordon électrique au niveau de cette prise. 

ƒ

 

L’appaireil fonctionne à une tension extrêmement basse de séciroté qui est conforme à la norme IEC60950.  
Ces conditions ne sont maintenues que si l’equipement auquel el est raccordé fonctionne dans les mêmes 
conditions. 

 

France et Pérou uniquement

Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre.  Si vos alimentations sont du type 
impédance à la terre, ce groupe doit être alimenté par une tension de 230 V (2 P+T) par le biais d’un 
transformateur d’isolement à rapport 1:1, avec un point secondaire de connesion portant l’appellation Neutre et 
avec raccordement direct à la terre (masse). 
 

Cordon électrique 

Il doit être agréé dans le pays d’utilisation. 
 

Etats-Unis et Canada 

ƒ

 

Le cordon doit avoir reçu l’homologation des UL et un certificat de la CSA. 

ƒ

 

Le cordon souple doit respecter, à titre minimum, les spécifications suivantes: 

  

Calibre 18 AWG 

 

Type SV ou SJ 

 

à 3 conducteurs 

ƒ

 

La cordon doit être en mesure d’acheminer un courant nominal d’au moins 10A. 

ƒ

 

La prise femelle de branchement doit être du type à mise à la terre (mise à la masse) et respecter la 
configuration NEMA 5-15P (15 A, 125 V) ou NEMA 6-15P (15 A, 250 V). 

© JBM Electronics Co. 

1-800-489-7781 

www.jbmelectronics.com

 

 

Содержание 900

Страница 1: ...Gateway 900 Installation Manual...

Страница 2: ...ibed in this manual are subject to change without notice Revision Level 5 0 Revision Date 1 3 2004 Copyright 2004 by JBM Electronics Co For further information contact JBM Electronics Co 4645 LaGuardi...

Страница 3: ...network Allows TCP IP devices to access a Legacy protocol network Provides host and terminal emulation for all polled protocols which allows up to 100 physical devices to be connected to one serial po...

Страница 4: ...to an IP network The Gateway can help protect the investment in Legacy devices when moving to a new network The Gateway s security software can be used to protect attached devices from unauthorized a...

Страница 5: ...the Gateway All of the protocol specific diagnostics such as LUSTATS Notify and Status and Sense Bytes are supported Extensions to the Telnet or SNMP commands are available as a special order Network...

Страница 6: ...ocol conversion Frame Relay Support The Gateway provides full support for Frame Relay networks including Supports up to 100 Logical Channels DLCIs Both CPE and Access Node configurations ANSI T1 617 A...

Страница 7: ...p to 56 KB The serial interface is RS 232C DCE with DTE Enabled through a cable adapter G50 adapter DB 25 Port 2 WAN Port supports Frame Relay or X 25 at speeds up to T1 E1 through the integrated DSU...

Страница 8: ...Adapter must be used The RS 232C cable and adapter are listed in the Cables Manual on the CD supplied with the unit 6 Connect the phone cable to the WAN Port Port 2 7 Plug the Gateway into a power out...

Страница 9: ...structions JBM Administrative Menu and other features Follow these instructions to access the Gateway through the Console Port 1 Verify your system is connected to the COM Port on the Gateway This can...

Страница 10: ...ve and must be entered in the appropriate case This userid and password is used for Console and Telnet access Note We recommend you change password using the instructions in the Gateway Operations Man...

Страница 11: ...ace definitions for the WAN connection The program usr sbin wancfg should be used to create the configuration file s It is a GUI ncurses based configurator that contains all wanpipe options as well as...

Страница 12: ...select wanpipe1 and hit the SELECT button 4 Choose WAN Protocol Definition and choose Frame Relay 5 Select Hardware Setup Select Adapter Type When selecting the Adapter Type note the PORT option Usual...

Страница 13: ...ame e g iptables o wp1_fr16 will give you an error Operation Mode WANPIPE is for IP Routing API is used for custom API applications DLCI Protocol Setup In this section leave everything as default Unle...

Страница 14: ...cators The Gateways have LED indicators that can be used to isolate problems The LEDs indicate the following activity LED COLOR FUNCTION NORMAL STATUS Power Yellow Signifies that power is available to...

Страница 15: ...Up to 115 200 bps Interface One Male DE 9 RS 232C DTE mode DCE mode with adapter cable Management Console Port CLI Access through async connection IP Protocol SNMP and Telnet LED Indicators Serial Por...

Страница 16: ...according to IEC 60 The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions France and Peru only This unit cannot be powered from IT supplies...

Страница 17: ...on acc s doit tre facile Vous ne pouvez mettre l appareil hors circuit qu en d branchant son cordon lectrique au niveau de cette prise L appaireil fonctionne une tension extr mement basse de s cirot q...

Страница 18: ...000 3 2 IEC 61000 3 3 EN 61000 3 3 ETSI EN 300 386 V1 2 1 1998 11 CE Statement Europe This product complies with the European EMC Directive 89 336 EEC Regulatory Notices FCC Statement This equipment h...

Страница 19: ...DC 20402 Stock No 004 000 00345 4 In order to meet FCC emissions limits this equipment must be used only with cables with comply with IEEE 802 3 CSA Statement This Class A digital apparatus meets all...

Страница 20: ...be reverse engineered or used for any other purpose other than in and with the computer hardware sold by JBM Electronics Extended Warranty Program JBM offers an extended warranty for the Gateway This...

Отзывы: