Parameter
Specification
Unit
QA Test
Limits
Conditions
Notes
ATO Turn-on time
5
ms
Functional
Amp connected and AC on, then input
signal applied
Auto Mute/ Turn-OFF Time
15
minutes
Functional
T before muting, after signal is
removed
Auto turn of time (T) must be 10 > T <15
Power on Delay time
3
sec.
Functional AC Power Applied
Transients/Pops
ATO Transient
5
mV-peak
10
@ Speaker Outputs
Turn-on Transient
50
mV-peak
100
@ Speaker Outputs
AC Line cycled from OFF to ON
Turn-off Transient
50
mV-peak
100
@ Speaker Outputs
AC Line cycled from ON to OFF
Efficiency
Stand-by Input Power
12
Watts
13
@ nom. line voltage
Maximum allowable input power under
nominal Input voltage and frequency,
HOT or COLD operation.
Power Cons.@rated power
180
Watts
187
@ 120V-60 Hz (Nom.line voltage)
90 Watts @ 4 Ohms nominal line voltage
Power Cons.@rated power
195
Watts
200
@ 230V-50 Hz (Nom.line voltage)
90 Watts @ 4 Ohms nominal line voltage
Protection
Short Circuit Protection
YES
--
Functional Direct short at output
Thermal Protection
65 deg. C
--
Functional @1/8 max unclipped Power
Temperature rise should not exceed 35K
rise
DC Offset Protection
YES
--
Functional DC present at Speaker Out leads
Relay or crowbar (for driver/fire
Line Fuse Rating
120VAC
2.5
Amps
Type-T or Slo Blo
External fuse with UL/SEMKO rated
holder
230VAC
1.25
Amps
Type-T or Slo Blo
External fuse with UL/SEMKO rated
holder
SUB200 (SCS200
.7
sys)
3
Содержание SUB200
Страница 11: ...SUB200 SCS200 7sys 10...
Страница 12: ...SUB200 SCS200 7sys 11...
Страница 13: ...SUB200 SCS200 7sys 12...
Страница 14: ...SUB200 SCS200 7sys 13...
Страница 15: ...SUB200 SCS200 7sys 14...
Страница 20: ...SUB200 SCS200 7sys 19...
Страница 21: ...R306 SUB200 SCS200 7sys 20...