JBL SR-X Series Скачать руководство пользователя страница 9

INPUT PANEL

Internal Network Mode Selector

All SR-X models are fitted with the internal network mode selector.

The ability to select the mode of operation provides the sound system user flexibility
in the system configuration, and also permits the system to be upgraded at a later
date. By simply removing the input panel and changing the position of a heavy duty
connector, the system can be configured as either a bi-amp or a passive system.
After replacing the input panel, the network position is indicated on the connector
plate panel. This provides a truly tamper resistant solution to avoid the horrors of a
mis-configuration.

In passive operation, a system can be operated with a minimum of only one
amplifier and no additional system controllers. In bi-amp operation, the system can
be operated for maximum transducer performance and will require the use of
additional amplifiers-and an electronic crossover (see "Crossovers and Controllers").
For Sub systems with more than one transducer, the same ability to select the mode
of operation is provided - but instead of bi-amp/passive selection, the input can be
configured for either parallel woofers (4 ohm) or individual transducer access
(2 x 8 ohm). This can be useful for assuring maximum power transfer from the
amplifier to the transducers.

Please Note: There are no passive network components in the circuit when the
Bi-amp mode is selected. (Except: SR4732X and SR4735X which retain a crossover
section between midrange and HF.)

Changing the Input Mode Connector

1. Remove 6 connector plate retaining screws and

remove the plate.

2. Turn plate over and locate the male connector.
3. Pull out connector and firmly place in socket of

desired system mode - you should be able to see
the yellow indicator in the desired mode window.

4. Replace plate and secure with 6 screws.

Please Note: For SR4715X - SR4719X, the connector is
split to permit discrete mode operation.

IN/OUT

±1 LF

IN/OUT

±2 NC

SR-X SERIES

Impedance: 8

Impedance: 16

±2 HF

±1 Full Range

BI-AMP

PASSIVE

Impedance: 8

JBL PROFESSIONAL
Northridge, CA USA

Made in U.S.A
Serial No.

9

IN/OUT

±1 PASS-THRU

IN/OUT

±2 PASS-THRU

SR-X SERIES

Impedance: 4

±2 LF

±1 LF
Impedance: 4

JBL PROFESSIONAL
Northridge, CA USA

Made in U.S.A
Serial No.

BOTH INDICATORS
DISCRETE MODE

±1 LF 8

±2 LF 8

Содержание SR-X Series

Страница 1: ...SR X Series Users Guide Part Number 981 00052 04 Rev A...

Страница 2: ...Do not block any ventilation openings Install in accordance with manufacturers instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus that prod...

Страница 3: ...verify that the stand is placed on a flat level and stable surface Route cables so that performers crew and audience will not trip over them and pull the speaker over Be sure to fully extend the legs...

Страница 4: ...of one nighters Pure titanium diaphragm compression drivers are used in all two three way models for high power handling and reliability Optimized Aperture horn driver combinations reduce throat disto...

Страница 5: ...X The large format 2447 compression driver coupled to an Optimized Aperture horn delivers great pattern control at very high levels with low distortion Dual LF Two Way Systems SR4731X Dual 12 two way...

Страница 6: ...5 mm diameter socket is provided for an optional pole JBL model SS3 BK to elevate a speaker such as the SR4702X or SR4722X above your subwoofer The socket is intended to accommodate speakers up to 100...

Страница 7: ...t notice SPECIFICATIONS DuraFlex The SR X loudspeaker system is finished in JBL s DuraFlex DuraFlex is tough and inherently flexible and it is extremely resistant to knocks scratches and scuffs The Du...

Страница 8: ...he cable side connections Selection of the appropriate wire gauge is important to system operation A cable that is too light will result in amplifier power being wasted due to the series resistance of...

Страница 9: ...f operation is provided but instead of bi amp passive selection the input can be configured for either parallel woofers 4 ohm or individual transducer access 2 x 8 ohm This can be useful for assuring...

Страница 10: ...e diagrams below represents a pair of wires E g both 1 and 1 connecting wires SR4715X 19X Pin 1 Hot as shipped SR4715X 19X Pin 2 Hot In Out LF 2 LF 1 In Out LF 2 LF 1 2 2 1 1 Passive Mode Bi Amp Mode...

Страница 11: ...www jblpro com 11 DSC 260 DIGITAL SYSTEM CONTROLLER ACCESS LAST NEXT PARAMETER STORE ENTER RECALL MUTE 1 MUTE MUTE MUTE MUTE MUTE 5 4 3 2 6 LIMIT 3dB 6dB 20dB LIMIT 3dB 6dB 20dB LIMIT 3dB 6dB 20dB LI...

Страница 12: ...s dbx DriveRack PA controllers Crown amplifiers and wiring connections It is very important that you are familiar with the previous sections of this Users Guide and also the dbx DriveRack PA and Crown...

Страница 13: ...p speaker cable High Output HF 2 LF 1 Sub 2 Sub 1 Mid Output Low Output HF 1 LF 2 Full Range 1 Pin 2 Mode Mid Output Low Output Full Range 1 Sub 1 Crown CE4000 Crown CE4000 Crown CE2000 Crown CE4000 C...

Страница 14: ...SR X F suspension system has a working load limit WLL of 400 lbs 181 kg per point with a 7 1 design factor When used with an appropriate track fit ting the SR X F suspension system has a working load...

Страница 15: ...nts MIN 5 1 design Factor or Local Standard Whichever is Greater Appropriate Track Fitting User supplied overhead suspension rated and certified Secondary Suspension Point Appropriate Track Fitting EG...

Страница 16: ...be sure to save the original shipping cartons because a charge will be made if replacement cartons are requested Payment of shipping charges is discussed in the next section of this warranty How to O...

Отзывы: