PB10
26
PB10 Testing Procedure (Cont.) (Revision 2 Only)
A. Power Amp Section
Resistance
Check
Resistance from S+ (SPK O/P) to GND should be >1M
Ω
(NO LOAD)
Resistance from V+ (C6 P+) to V- (C8 P-) gradually Fully CHARGED should read >10k
Ω
Resistance from V+ (C6 P+) to S+ (SPK O/P) should read >1M
Ω
Resistance from V- (C8 P-) to S+ (SPK O/P) should read >1M
Ω
2. Power Up LED RED
With a 5mV signal to Low level input, LED should change to GREEN
-Voltage measurements (DVM)
OP AMP
LED
P-U4(1)
P-U4(7)
RED
0Vrms
8VDC
GREEN
6.3Vrms
-10.7VDC
3. D.C. Operation
-Voltage measurements (DVM) on CLASS D POWER AMP
Between
V+
Q4(E)
Q1(C)
Q10(C)
U7(1)
U7(2)
U7(4)
U7(6)
U7(7)
U7(8)
And This
Point
GND
V-
GND
GND
GND
GND
GND
GND
GND
GND
Get this
Reading
45.9V
0V
-45.9V
0V
-45.9V
-45.7V
-45.5V
0V
0V
4.7V
4. Check Switching Frequency
•
Oscilloscope -
USE THE PROBE TIP TO U6(7) TO GND
•
Reading /-10%,22Vp-p
B. Pre Amp Section
Line Level Input Sensitivity
-Set up
Turn level, X’OVER FREQ POT Fully CW and LFE switch off
Generator Set at 100mV@50Hz
Signal to Line level input
Содержание PowerBass PB10
Страница 41: ...41 PB10 PCB version 6 3 7 0 Revision 1 Only ...
Страница 42: ...42 PB10 PCB version 6 3 7 0 Revision 1 Only ...
Страница 43: ...43 PB10 PCB version 6 3 7 0 Cont Revision 1 Only ...
Страница 44: ...PB10 PCB version 6 4 Power Amp Only Revision 1 Only ...
Страница 45: ...PB10 PCB version 7 2 Revision 1 Only ...
Страница 46: ...PB10 PCB version 7 2 Revision 1 Only ...
Страница 47: ...PB10 PCB version 7 2 Revision 1 Only ...
Страница 51: ......
Страница 52: ......
Страница 53: ...53 PB10 Revision 2 Schematic Diagrams PREAMP ...
Страница 54: ......