Remove red wire (A) from input PC board as shown in
above drawing.
Place wire from transformer primary (F, G, H, or I) that
corresponds to the desired wa
tt
age needed to tap (see
chart of values on page 1) to the now open former
loca
ti
on of the red wire (A). **Please note above example
shows red wire (F) connected to input PC board which is
the 300W tap for 70V use.
Unplug connector a
tt
ached to the end of the red wire
(A) and black wire (B) from the PC board and set aside.
This cable conne
cti
on is no longer needed for use with
the transformer.
Attach
yellow wire (D) and green wire (C) to the now
open former loca
ti
on of the connector from the red
wire (A) and black wire (B). This is the loca
ti
on for the
po
siti
ve “+” and nega
ti
ve “- “ wires from the
transformer secondary.
8
9
9
10
11