JBL MPA1100 Скачать руководство пользователя страница 18

17

Specifications

Load & Measure-
ment Conditions

Output RMS Power in Watts

8 ohms/channel
20 Hz – 20 kHz
0.1% THD

MPA1100 MPA750 MPA600 MPA400 MPA275

450
475
500

350
375
400

250
260
275

160
170
175

8 ohms/channel
20 Hz – 15 kHz *
0.1% THD

4 ohms/channel
20 Hz – 20 kHz
0.1% THD

4 ohms/channel
20 Hz – 15 kHz *
0.1% THD

8 ohms/channel
1 kHz
1% THD

4 ohms/channel
1 kHz
1% THD

2 ohms/channel
1 kHz
0.1% THD, 

±

1 dB

8 ohms bridged mono
20 Hz – 15 kHz *
0.1% THD

4 ohms bridged mono
1 kHz
0.1% THD, 

±

1 dB

60 Hz AC

Power Mains

110 VAC
115 VAC
120 VAC

660
690
720

650
700
750

500
550
600

350
375
400

225
250
275

900

1000
1100

480
510
550

400
425
450

275
290
300

180
190
200

740
770
800

700
760
825

550
610
675

400
425
450

275
300
400

1000
1100
1200

900
950

1000

650
725
800

500
550
600

350
375
400

1200
1300
1400

1800
2000
2200

1800
1900
2000

1300
1450
1600

1000
1100
1200

700
750
800

2400
2600
2800

8 ohms bridged mono
20 Hz – 20 kHz
0.1% THD

1300
1400
1500

1000
1100
1200

700
750
800

450
500
550

110 VAC
115 VAC
120 VAC

110 VAC
115 VAC
120 VAC

110 VAC
115 VAC
120 VAC

110 VAC
115 VAC
120 VAC

110 VAC
115 VAC
120 VAC

110 VAC
115 VAC
120 VAC

110 VAC
115 VAC
120 VAC

110 VAC
115 VAC
120 VAC

110 VAC
115 VAC
120 VAC

Table 4. Output Power Ratings When Used With 110, 115 & 120 VAC 60 Hz Mains

Содержание MPA1100

Страница 1: ...P r o f e s s i o n a l A m p l i f i e r Clip 10dB 20dB Signal Present Clip 10dB 20dB Signal Present Power Protect 1 CHANNEL 2 18 10 8 6 4 12 14 24 0 2 48 18 10 8 6 4 12 14 24 0 2 48 Clip 10dB 20dB...

Страница 2: ...HE RISK OF ELECTRIC SHOCK DO NOT REMOVE THE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL VORSICHT UM DAS RISIKO EINES ELEKTRISCHEN SCHLAGES ZU VERMINDERN ABDEC...

Страница 3: ...peaker Outputs 5 Figure 5 Typical Unbalanced Connection 6 Figure 6 Portable Balanced System 6 Figure 7 Installed Balanced System 6 Figure 8 Ground Bus Connection 6 Figure 9 Jumper Positions for XLR Po...

Страница 4: ...ort within the rack must be used in portable applica tions Open Input Architecture Slots Provided with each MPA Series amplifier is a standard input module This module and the upper input cover panel...

Страница 5: ...6 7 13 23 22 23 22 25 29 24 27 28 26 30 31 31 25 29 24 27 28 26 30 31 31 Figure 2 Rear and Front Panel for 2 Space High Models MPA275 MPA400 MPA600 Figure 3 Rear and Front Panel for 3 Space High Mode...

Страница 6: ...ce is 20 kilohm balanced 10 kilohm unbalanced as is typical of JBL amplifiers The input jacks are located on a removable panel which has a toggle switch for 1 bridged mono 2 normal stereo or 3 paralle...

Страница 7: ...ld at the source with no connection to pin 1 at the amplifier If after wiring the input as shown above any hum or buzzing is present connect the GND terminals of all amplifiers together This bus shoul...

Страница 8: ...the rear panel 5 Install the input ribbon cable and remount the Standard Input Module securely To Parallel the Inputs 1 Locate the selector switch adjacent to the CHANNEL 1 input XLR connector and se...

Страница 9: ...MIN CH 2 CH 1 DUAL CHANNEL OUTPUT CONNECTOR STEREO 4 OHM MIN PER CH CONNECT ONE SPEAKER LOAD ONLY Use Either Binding Posts or Stereo Speakon but not both 2 2 1 1 BRIDGED MONO MODE CAUTION Output volt...

Страница 10: ...hese levels in perspective music played at one third average power will be in a state of constant clipping and this power level is about the greatest one can obtain without completely obliterating the...

Страница 11: ...1400 x 2 56 0 A 23 4 A 11 8 A 8 8 510 x 2 18 6 A 9 8A 4 8 A MPA750 4 4 760 x 2 30 0 A 14 8 A 6 8 A 0 8 A 2 2 1000 x 2 39 4 A 21 4 A 10 6 A 8 8 425 x 2 13 6 A 8 6 A 3 6 A MPA600 4 4 610 x 2 23 0 A 13 4...

Страница 12: ...A 2 2 1400 x 2 28 0 A 11 7 A 5 9 A 8 8 510 x 2 9 3 A 4 9A 2 4 A MPA750 4 4 760 x 2 15 0 A 7 4 A 3 4 A 0 4 A 2 2 1000 x 2 19 7 A 10 7 A 5 3 A 8 8 425 x 2 7 8 A 4 3 A 1 8 A MPA600 4 4 610 x 2 11 5 A 6 7...

Страница 13: ...proaches maximum tempera ture Illuminated steadily plus flashing during thermal muting Illuminated steadily during non thermal muting Typical Power Up Operation Power Down Behavior When the amplifier...

Страница 14: ...bnormal PROTECT may flash too CLIP flashing at full LEVEL display indicates the amp has reached full power clipping and the limiter is acting to prevent severe overdrive A steady CLIP glow after the f...

Страница 15: ...hose models rated at 2 ohms see Specifications the LEVEL 10 display should not be on more than about half the time with only occa sional clipping Protection Circuits The essence of high efficiency lig...

Страница 16: ...f 15 dB If this does not arrest the temperature rise in case of an output short or blocked ventilation the amplifier will finally enter full muting which causes full shutdown of the output bias circui...

Страница 17: ...oad grounding relay with internal fault fuses Complementary linear high efficiency outputs 3 step on MPA1100 2 step on MPA750 MPA600 MPA400 1 step on MPA275 100 120 220 240 Vac 50 60 Hz See Charts on...

Страница 18: ...720 650 700 750 500 550 600 350 375 400 225 250 275 900 1000 1100 480 510 550 400 425 450 275 290 300 180 190 200 740 770 800 700 760 825 550 610 675 400 425 450 275 300 400 1000 1100 1200 900 950 100...

Страница 19: ...1 THD 1 dB 50 Hz AC Power Mains 220 VAC 230 VAC 240 VAC 660 690 720 220 VAC 230 VAC 240 VAC 650 700 750 500 550 600 350 375 400 225 250 275 220 VAC 230 VAC 240 VAC 900 1000 1100 220 VAC 230 VAC 240 VA...

Страница 20: ...TECT display is visible amplifier has muted due to extreme overheating Fan should be running at full speed and unless ventila tion is blocked operation should resume within one minute B The amplifier...

Страница 21: ...speed 50 60 C Fan Speed rises gradually from slow to full 75 C PROTECT LED starts flashing 85 C PROTECT flash rate increases and CLIP starts to glow steadily The limiter will begin to reduce amplifie...

Страница 22: ...ty without prior authorization You may obtain that authorization by contacting the factory or repair facility directly Please ship amplifiers in original packing materials or equiva lent to prevent fu...

Страница 23: ...Part No TD 007500 OB PS137 2 A Harman International Company JBL Incorporated 8500 Balboa Boulevard Northridge California 91329USA...

Отзывы: