JBL MA6004 Скачать руководство пользователя страница 3

INSTALLATION 

POWER CONNECTIONS

The amplifier requires a reliable 
connection to the boat’s electrical 
system in order to perform optimally. 
See Figures 1 and 2 for terminal con-
nection locations. Please adhere to 
the following instructions carefully: 

Ground Connection

Connect the amplifier’s Ground (GND) 
terminal to the battery’s negative terminal,
using a ring terminal. Refer to the wire gauge
chart to determine minimum wire gauge size. 

Power Connection

Connect a wire (see chart at right for
appropriate gauge) directly to the positive
battery terminal, and install an appropriate
fuse holder within 18" of the battery terminal.

Do not install the fuse at this time.

Route

the wire to the amplifier’s location, and
connect it to the amplifier’s Positive (+12V)
terminal. Be sure to use appropriate 
grommets whenever routing wires through
a bulkhead or other obstruction. 

Failure to

adequately protect the positive wire from
potential damage may result in a fire.

When

you are done routing and connecting this
wire, you may install the fuse at the battery.

Remote Connection

Connect the amplifier’s Remote (REM) 
terminal to the source unit’s Remote Turn-
On lead using a minimum of 18-gauge wire.

NOTE:

If your source unit does not have 

a remote turn-on connection, connect 
the amplifier’s (REM) terminal to a wire
that pr12V when the boat’s acces-
sories are on or when the key is switched
on. If no such circuit exists, install a
switch. See Figure 3.

Figure 3.

Install a switch for the Remote

Turn-On lead.

Speaker Connections

Refer to the application guides on the
pages that follow. Speaker connections
should be made using a minimum of 
16-gauge wire.

Wire Gauge Chart

Amplifier

Maximum

Minimum 

Model

Current Draw

Wire Gauge

MA6002

22A 

#8 AWG

MA6004

40A 

#8 AWG

These recommendations assume 10' – 12'
wire runs. If your amplifier will be mounted
farther than 12' from the boat’s battery, use
a larger gauge.

Figure 2.

Terminal connection end plate for MA6002.

Figure 1.

Terminal connection end plate for MA6004.

NC

NO

+12V

AMP REM

Отзывы: