JBL LS Sub 250W Powered Sub Amp
LINE VOLTAGE
Yes/No
Hi/Lo Line
Nom.
Unit
Notes
US 120vac/60Hz
Yes
108-132
120
Vrms
Normal Operation
EU 230vac/50-60Hz
Yes
207-253
230
Vrms
Normal operation, MOMS
Parameter
Specification
Unit
QA Test Limits
Conditions
Notes
Amp Section
Type (Class AB, D, other)
D
n/a
n/a
Load Impedance (Driver min)
4
Ohms
n/a
Nominal
System average impedance from
20 to 500 Hz
8.65
Ohms
n/a
Reference
Driver size
12
inches
n/a
Reference
Rated Output Power (120VAC)
250
Watts
240
Domestic version only 120
Rated Output Power (230VAC)
269
Watts
250
EU Version only 230
VAC-50-60 Hz
AVG RMS Dynamic Power
210
Watts
270
Average RMS power, 3/20
Cycles 50 Hz, Driven 6dB
above its input sensitivity
sensitivity, average of the first
THD @ Rated Power
0.5
%
1
22k filter
THD @ 1 Watt
0.2
%
0.5
22k filter
DC Offset
50
mV-DC
50
@ Speaker Outputs
Damping factor
>50
DF
20
Measured at
amplifier board
Measured at the speaker
cable. 150 Watts @ THD <
Input Sensitivity
Input Frequency
50
Hz
50
Nominal Freq.
L&R
22
mVrms
±1dB
To 1 Watt
Single input driven
LFE input
22
mVrms
±1dB
To 1 Watt
Single input driven, LFE switch
System Gain
90.9
n/a
Reference
Single input driven Normal
System Gain in dB
39.17
dB
Reference
Single input driven Normal
Signal to Noise
SNR-A-Weighted
100
dBA
95
relative to rated
A-Weighting filter
SNR-unweighted
90
dBr
85
relative to rated
22K filter
SNR rel. 1W-unweighted
65
dBr
60
relative to 1W
22K filter
Residual Noise Floor
1.5
mVrms(max)
2
Volume @max, w/
A/P Swept
Bandpass
Line level inputs must be
terminated using 1KOHM
Input Impedance
Line Input (L, R,LFE)
10K
ohms
n/a
Nominal
Filters
LP filter Variable
50-150 Hz
± 10
4th order variable (24dB/oct)
Subsonic filter (HPF) 2rd Order
Fixed
Friend circuit
Fixed
LFE Low pass
200>LP<500 Hz
LFE input driven
Limiter
THD at Max. Output Power
N/A
N/A
functional
Maximum Output
Maximum THD as a result of
Features
--
Volume pot Taper (lin/log)
LOG
--
functional A
Taper
Phase switch
0-180
deg
functional
LP Filter defeat switch
YES
functional
Disables LP filter, intended for
Input Configuration
Line In (L,R)
YES
--
functional
LFE use either L or
R inputs, LFE
switch must be
Dual RCA jack
Signal Sensing (ATO)
Auto-Turn-On (yes/no)
YES
functional
ATO Input test frequency
50
Hz
functional
ATO Level L, R or LFE Mode
1.5
mV
functional
Maximum acceptable level.
ATO Turn-on time
5
ms
functional
Amp connected and
AC on, then input
Auto Mute/ Turn-OFF Time
5-15
minutes
5-15
T before muting,
after signal is
Auto turn of time (T) must be
5 > T < 15 Minutes
2
LS120P
Содержание LS Series
Страница 5: ...4 LS120P...
Страница 11: ...10 LS120P...
Страница 12: ...11 LS120P...
Страница 14: ...13 LS120P...
Страница 15: ...14 LS120P...
Страница 16: ...15 LS120P...
Страница 17: ...16 LS120P...
Страница 18: ...17 LS120P...
Страница 23: ...22 LS120P...
Страница 24: ...23 LS120P...
Страница 25: ...24 LS120P...
Страница 26: ...25 LS120P...
Страница 27: ...26 LS120P...
Страница 28: ...27 LS120P...
Страница 29: ...28 LS120P...
Страница 30: ...29 LS120P...
Страница 31: ...30 LS120P...
Страница 32: ...31 LS120P...
Страница 33: ...32 LS120P...