JBL Intellivox ADC V90 Mark II Скачать руководство пользователя страница 15

JBL Professional

®

 Intellivox ADC Installation Manual

15

201402/ADCIM

CORRECTION EQ AND HIGH-PASS FILTER

Many building PA systems will include some provision 
for equalisation (EQ) adjustment at the signal processing 
stage, or within the power amplifier (as with the JBL AXYS 
PB-400 and PB-800 amplifiers). Adjusting EQ to achieve 
maximum system intelligibility is a normal part of the 
commissioning process, though it should be noted that 
measured intelligibility will be greatly affected by several 
other factors not immediately under the designer’s control, 
such as reverberation time and ambient noise levels.  If 
external EQ adjustment is not available, it may be desirable 
in some applications to modify the frequency response of the 
loudspeaker itself.

The frequency response can be altered by means of two 
switches labelled ‘EQ’ and ‘HPF’. These switches are located 
behind the inspection plate as indicated in fig.9.2 (Model 
V90) and fig.9.3 (Model H90).

The EQ switch has two positions. The EQ is disabled if the 
switch is in the ‘Flat’ position. The mid-cut EQ correction 
is indicated in fig.10.1 (Model V90) respectively fig.10.3 
(Model H90). The factory default setting is with EQ enabled 
(flattest SPL versus frequency response). If the EQ is 
disabled the maximum achievable SPL is somewhat higher, 
at the expense of a SPL response that is less flat.

The HPF (high-pass filter) switch also has two positions. 
The high-pass filter is disabled if the switch is in the ‘Flat’ 
position. The frequency response of the high-pass filter 
is indicated in fig.10.2 (Model V90) respectively fig.10.4 
(Model H90). The filter response is slightly dependent on 
the tap setting, the curves are valid for the 100 W tap. The 
factory default setting is with the high-pass filter enabled, 
this setting is most suitable for voice applications. 

Note that the high-pass filter might have to be disabled in 
case of 3rd-party line monitoring applications that make 
use of a DC signal. DC will be blocked by a series capacitor 
if the high-pass filter is enabled.

If the monitoring system uses an end-of-line unit, and DC 
input to the loudspeaker should be blocked, the high-pass 
filter should be enabled. If the monitoring system is to be 
used in conjunction with the loudspeaker(s), without end-
of-line unit, the high-pass filter should be disabled. 

Note that this does not apply to the integral 
load monitoring of the JBL AXYS PB-400/PB-800 
Industry Amplifiers; these amplifiers do not use a 
DC signal for load monitoring purposes.

SECURING THE FRONT GRILL

Option 1. 

After making the connections and setting the 

power tapping, the front grill may be replaced. Do not 
replace the protective foam! Align the four locating spigots 
with the four larger holes in the back of the grill frame and 
push the grill back on, ensuring that all four spigots locate 
positively with the retaining clips within the holes. 

Option 2. 

The front grill may be secured more permanently 

with the (supplied) M4 security screws. These need to be 
fitted one at a time before replacing the grill. 

fig.10.1 - V90 correction EQ 

fig.10.3 - H90 correction EQ

fig.10.4 - H90 high-pass filter

fig.10.2 - V90 high-pass filter

Содержание Intellivox ADC V90 Mark II

Страница 1: ...Installation Manual Intellivox ADC V90 H90 Mark II models Part Nos 576125 577125 577135 576126 577126 and 577136 EN54 24...

Страница 2: ...models Document references Datasheet s 201104 V90MKII_2 x V90 datasheet 201104 H90MKII_2 x H90 datasheet Other references ITT report No 5136 BA 11 Notified product certification body Name Scientific a...

Страница 3: ...te names mentioned in this manual may be registered trademarks or copyrights of their respective companies They are used here for indicative purposes only The information contained in this manual has...

Страница 4: ...JBL Professional Intellivox ADC Installation Manual 4 201402 ADCIM This page has been left blank intentionally...

Страница 5: ...7 What s in the packaging 8 3 Installation Guide 9 Preparing For Installation 9 Intellivox ADC Connections 9 Mechanical Installation 10 Acoustic Centre 10 Mounting Options 11 Mounting Procedure 13 Wir...

Страница 6: ...s radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Only use attachments accessories specified by the manufacturer 10 Use only with the cart stand tripod brac...

Страница 7: ...glass thermal fuse and ceramic terminal block EQ correction and high pass filter This manual covers Wiring and connection details Mechanical installation of the loudspeaker Please note that a full ran...

Страница 8: ...is document ADC Datasheet Box containing REF ITEM QTY USE A Mounting brackets 2 Speaker mounting B 30 mm hex headed screws with washers and wall plugs 4 Mounting bracket fixings wall C M5 x 12 mm pan...

Страница 9: ...plane This restriction does not apply to the Model H90 which is intended to be tilted downwards INTELLIVOX ADC CONNECTIONS The Intellivox ADC range loudspeakers are designed to be connected to 100 V o...

Страница 10: ...cker see fig 3 The horizontal position is on the vertical centre line When calculating the positions for the mountings see below the distance from the acoustic centre to the top or bottom of the louds...

Страница 11: ...radiating angle of the unit is correct fig 4 2 Acoustic centre reference point for H90 Reference point for acoustical mounting position H90 fig 4 3 H90 further mounting information A C H90 B MOUNTING...

Страница 12: ...mation 3 The third method is to mount the column within a recess in the wall or dedicated mounting panel so that the front of the unit is flush This is a specialised mounting situation which will be e...

Страница 13: ...s on one or both brackets if necessary 6 Attach the brackets to the rear of the loudspeaker using the M5 x 12 pan head screws and shakeproof washers supplied The 10 mm diameter holes allow screwdriver...

Страница 14: ...g location the wiring scheme as indicated in fig 8 2 can be used Note that the application dependent safety regulations should be consulted in order to determine the proper grounding scheme TAP SETTIN...

Страница 15: ...on The frequency response of the high pass filter is indicated in fig 10 2 Model V90 respectively fig 10 4 Model H90 The filter response is slightly dependent on the tap setting the curves are valid f...

Страница 16: ...Pilot tones of other frequencies and or levels may be used if the fault monitoring system demands them the illumination of the LED is not essential for such a system to operate correctly SPEAKER PROTE...

Страница 17: ...02227 Intellivox hinge bracket 90 RAL 9007 802005 Intellivox swivel bracket 90 RAL 9007 806668 Intellivox swivel bracket 45 RAL 9007 806678 Intellivox wall bracket set 2 pcs 25 mm RAL 9010 802225 Inte...

Страница 18: ...JBL Professional Intellivox ADC Installation Manual 18 201402 ADCIM This page has been left blank intentionally...

Страница 19: ...JBL Professional Intellivox ADC Installation Manual 19 201402 ADCIM This page has been left blank intentionally...

Страница 20: ...JBL Professional 8500 Balboa Boulevard Northridge CA 91329 U S A Copyright 2014 JBL Professional www jblpro com...

Отзывы: