Installation
RACK MOUNTING
CAUTION
: Before you begin, make sure your amplifier is disconnected from the power source.
The DA series amplifiers are intended to be installed in a standard 19-inch equipment rack with the
supplied with rack mount ears in a 1U rack space (rack mount bolts and nuts are not included).
Installing a DA series amplifier in a rack:
1. Attach the rack ear brackets to the sides of the amplifier using the provided machine screw
fasteners into the threaded holes (1 ± 0.1Nm recommended torque).
2. Install into rack and connect cabling.
PROPER COOLING
When using an equipment rack, mount units directly on top of each other. Close any spaces in the rack with
blank panels. (Open spaces will reduce cooling efficiency.) Once mounted in the rack, ensure the sides of
the amplifier are well ventilated and that the fan openings are not obstructed. The rack should be a
minimum of 2 inches (5.1cm) away from the sides of the amplifier.
Air flow is side-to-side.