Limiter
THD at Max. Output
Power
n/a
n/a
functional
Maximum Output Power
Maximum THD as a result of limiting.
Features
—
Volume pot Taper
(lin/log)
LOG
—
functional
HP Speaker out
functional
Refer to filter section
Input Configuration
Line In & LFE
YES
—
functional
LR dual RCA jack
Spkr/Hi Level In
YES
—
functional
Spring type connector
Signal Sensing (ATO)
Auto-Turn-On
YES
functional
Auto - on selection switch in Auto
Bicolor LED (Green=signal/ red= No signal)
ATO Input test frequency
40
Hz
functional
“
ATO Line level in
5
mV
functional
"
ATO Level Speaker in
50
mV
functional
"
ATO Turn-on time
5
ms
functional
Amp connected and AC on, then input signal
applied
Auto Mute/ Turn-OFF
Time
15
minutes
17
T before muting, after signal is removed Auto turn of time (T) must be 3 > T < 15
Minutes
Power on Delay time
0.1
sec.
5
AC Power Applied
Transients/Pops
ATO Transient
5
mV-peak
50
Turn-on Transient
2
Vpk-pk
2
@ Speaker Outputs
AC Line cycled from OFF to ON
Turn-off Transient
2
Vpk-pk
2
@ Speaker Outputs
AC Line cycled from ON to OFF
Efficiency
Efficiency
65
%
64
Nominal Line voltage 120 VAC / 230 VAC
Stand-by Input Power
15
Watts
18
@ nom. line voltage
Auto turn of time (T) must be 3 > T < 15
Minutes
Power Cons. @ rated
power
76
Watts
80
@ nom. line voltage
75 Watts @ 4 Ohms nominal line voltage
Protection
Short Circuit Protection
YES
functional
Direct short at output
Amplifier should resume operation after short
circuit condition removal
Thermal Protection
YES
functional
@1/8 max unclipped Power IEC Noise
using driver load
Temperature rise in accessible metal parts
should not exceed 35K rise for 120v version
or 30K rise for European versions (refer to
requirements sheet).
Line Fuse Rating
US (120v) version
Amps
0.6
Type-T or Slo Blo-250 V
Internal fuse
EU
Amps
TBD
Type-T or Slo Blo-250 V
External fuse with UL/SEMKO rated holder
5
Amplifier/Subwoofer
ARC SUB10/DS-10