JBL 7130 Скачать руководство пользователя страница 6

Line/MIC 2 - Input - Line/MIC 1 9-pin socket requiring either two 

copper jumpers between pins 4 & 5 
and 8 & 9, or a  J B L 5901 universal 
microphone input transformer or 
5195 matching/bridging trans-
former allowing for either a 
balanced or unbalanced input. 

Output Unbalanced 600 SI direct or 600 n 

balanced up to an output level of 

+18 dBm. 

Input 1 & Balanced input impedance of  1 5 k f t 
Input 2 up to a level of +21 dB without 

optional 5195 matching/bridging 
transformer. 

Balanced input impedance of 600 ft 
using a 620 ft resistor connected to 
terminals HI and  L O , up to a level 
of +21 dBm with optional 5195 
transformer. 

Unbalanced 15 k ft input 
impedance or 600 ft input 
impedance using a 620 ft 
resistor connected to terminals 
G N O a n d  D I R E C T . 

MIC 1 Push-lock/push-release switch 

Line allowing input to be used for either 

microphone or line. 

MIC 2 Push-lock/push-release switch 
Line allowing input to be used for either 

microphone or line 

MIC 2 - Input - MIC 1 Balanced input impedance of 600 O. 

using a 620

 n

 resistor connected to 

terminals HI and  L O , up to a level 

of +21 dBm with optional 5195 
transformer. 

N O T E : When the  J B L 5901 

universal microphone input 
transformer is used, the 
microphone pad and control 
cannot be used to prevent 
transformer saturation if 

excessive input signal levels 
occur. See  S P E C I F I C A T I O N S 

(Input Overload) for maxi-

mum input. 

F I G U R E

 2 

Содержание 7130

Страница 1: ...JBL 7130 INSTALLATION AND SERVICE MANUAL...

Страница 2: ...the original design specifications unless otherwise stated PRODUCT SPECIFICATIONS Maximum Gain Direct Input Unbalanced 1 Line 30 dB high 2 Microphone 62 dB high Z Balanced Input1 Line with 5195 84 dB...

Страница 3: ...perating switches meter threshold and level controls except for MIC LINE input selector switches are located on the front panel Figure 1 Input Connections Input connections to the 7130 may be either d...

Страница 4: ...transformer from the appropriate 9 pin socket 2 Install two 12 AWG copper jumpers per Figure 6 JUMPER PINS 8 9 JUMPER PINS 4 5 OPTIONAL INPUT TRANSFORMER 5195 or 5901 SWITCH S E L E C T S INPUT OPTION...

Страница 5: ...Limit modes of 7130 Meter Select Selects VU meter function Gain Reduction Line Out Threshold Adjustable control which sets the level above which compression or limiting occurs Power Switch Applies po...

Страница 6: ...th optional 5195 transformer Unbalanced 15 k ft input impedance or 600 ft input impedance using a 620 ft resistor connected to terminals GNOand D I R E C T MIC 1 Push lock push release switch Line all...

Страница 7: ...ER MODE COMPRESSOR MODE 6 A Control set to B Input signal 0 dBm C Control set to D Control level set for 1 10 dBm at A Control set to B Control set to C Input signal 0 dBm D Control level set for 10 d...

Страница 8: ...e the following procedure to change the voltage range MOLEX COMMONING CONNECTOR WARNING THIS SECTION OF THE MANUAL CONTAINS S E R V I C E INSTRUCTIONS FOR USE BY Q U A L I F I E D S E R V I C E PERSON...

Страница 9: ...V AC commoning wire code Comming Connector Wire Spacer Terminal Color Wire Origin Required 1 Note 1 Power Cord 2 Wht Power Switch 3 Yes 4 Blk Wht Power Switch 5 Blk Power Transformer 6 Yes 7 Blk Wht...

Страница 10: ...re guide strip the outer covering from the new power cord and cut each wire to the appropriate length per the local wiring code E Strip 5 mm 3 16 in from the longest wire and tin F Insert the wires fr...

Страница 11: ...tmeter to the OUTPUT screw terminal board DIRECT and GND and terminate with a 600 ft load 3 Connect the test oscillator s 600 output terminated by 600 ft load to LINE 1 screw terminal board DIRECT and...

Страница 12: ...WARNING THIS SECTION OF T H E MANUAL CONTAINS SERVICE INSTRUCTIONS FOR USE BY QUALIFIED S E R V I C E PERSONNEL ONLY 11 7130 Exploded View and Parts List FIGURE 13...

Страница 13: ...ding head screw 16 47896 7 6 32 x 5 16 hex head screw 17 59893 1 Green LED lens 18 54953 1 Power switch 19 13189 2 Capacitor 20 59294 1 Chassis Item JBL Part No Qty Description 21 89654 6 6 x 3 8 hex...

Страница 14: ...Block Diagram 13 WARNING THIS SECTION OF THE MANUAL CONTAINS S E R V I C E INSTRUCTIONS FOR USE BY QUALIFIED S E R V I C E PERSONNEL ONLY...

Страница 15: ...00A DVM GenRad W5MT3W Variable transformer GenRad 1523 1523P2 Graphic level recorder set GenRad 1840 A Output power meter HP 350B Attenuator set HP 339A Distortion measurement set HP 400 F L AC voltme...