4. PrESEtS

NEtWork CoNNECtIoNS

Two latching 5-pin XLR connectors are fitted for 
RS-485 network interconnections. A PC running 
WinControl may be connected, via an appropriate 
interface (either RS-232 to RS-485 or USB to RS-485) to 
the Input connector, if control and monitoring during 
operation are required. The Link connector (male) is 
to facilitate easy connection to another WinControl-
supported device (e.g. an adjacent enclosure).

The network connectors should be wired as follows:

See page 11 for information regarding suitable 
network cable types. See Section 7 (Configuring with 
WinControl) for more information about network 
operation and software options.

The UniAmp 1214’s DSP section includes 8 Presets; 
memory locations in which sets of configuration 
parameters can be stored. These permit the 
loudspeaker cabinet to be “fine-tuned” to suit 
different types of programme material and venue.

When a settings file is loaded into the unit from a 
PC, the user can specify in WinControl which Preset 
memory it will be loaded into.

rECALLING PrESEtS

The simplest method of recalling a previously-saved 
Preset is via WinControl. This necessitates a network 
connection to the loudspeaker system. Refer to the 
WinControl Help files for further information.

If a network connection is not in place, or a PC with 
WinControl is unavailable, Presets may be recalled 
manually using the Reset & Preset Control button. 
This button is hidden behind a small access hole on 
the amplifier module’s conector panel, and can be 
accessed with an implement such as a fine jewellers’ 
screwdriver or a straightened-out paper clip.

A single short press (< 1 sec) on this button will 
increment the current Preset number, i.e. if the system 
is currently running Preset 2, pressing the button will 
load Preset 3. While the button is pressed, the Status 
LED will change colour from green to red. Loading of 
the next Preset is confirmed by the LED flashing the 
appropriate number of times, i.e., it will flash 3 times 
when Preset 3 is loaded. Using this method, repeated 
button presses will load each Preset in turn.

Note that the amplifier module always 
powers-up with the last-used Preset active. 
Note also that a long (> 1 sec) button press 

has a different function (see following page).

PIN #

Function

1

Screen

2

Data Tx +

3

Data Tx -

4

Data Rx -

5

Data Rx +

1

2

3

4

5

5

4

3

2

1

Содержание 1214

Страница 1: ...User Guide JBL Professional UniAmp Power Amplifier Module Model 1214...

Страница 2: ...er s Notice and disclaimer No part of this manual including the software described in it may be reproduced transmitted transcribed stored in a database system or translated without the express written...

Страница 3: ...ons 4 2 Introduction 5 Applicable models and variants 5 3 Connector and wiring details 6 Connector panel diagram 6 AC Mains 6 Audio connections 7 Network connections 8 4 Presets 8 Recalling Presets 8...

Страница 4: ...specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart app...

Страница 5: ...inControl also permits constant monitoring of all units in a multiple cabinet system during operation WinControl is available as download from www jblpro com This guide does not cover any aspects of t...

Страница 6: ...not independently fused The full load power consumption of the amplifier module is model dependant but does not exceed 250 VA please refer to the individual data sheets for model specific information...

Страница 7: ...ides a safety ground connection Warning If the mains switch of the UniAmp 1214 is not readily accessible after installation to disconnect the unit when necessary the mains connection to the UniAmp 121...

Страница 8: ...loaded into Recalling Presets The simplest method of recalling a previously saved Preset is via WinControl This necessitates a network connection to the loudspeaker system Refer to the WinControl Hel...

Страница 9: ...the LED illuminates red and an error indication is also communicated via WinControl 3 To confirm which Preset is being loaded see Recalling Presets Section 4 4 Unit identification if the LED is set in...

Страница 10: ...then be connected to either the PC s 9 pin COM port in the case of a RS 232 to RS 485 interface or a USB port in the case of a USB to RS 485 interface Basic software options WinControl allows the vari...

Страница 11: ...the specifications given below which are those of a common commercially available cable are likely to be suitable Additional information regarding network connections and grounding strategies may be o...

Страница 12: ...JBL Professional 8500 Balboa Boulevard Northridge CA 91329 U S A Copyright 2014 JBL Professional www jblpro com...

Отзывы: