13
DOP 250 pump
The DESMI pump is used to pump collected oil from the collection well to the
storage tanks. It should run in the 'forward' direction as indicated at the
directional control valve located on the control panel. The maximum hydraulic
input to the pump is 42 gpm, which is set at the flow control valve. Pump
speed is controlled by varying the position of the directional control valve
handle from 0 to full flow. Operate the pump in reverse for 5-10 seconds to
clear the piping and pump before terminating skimming operations and to
prevent water from freezing in the pump cavity.
3 STORAGE AND TRANSPORT
A Storage
The DIP 500 can be stored inside a building, outside in a secure area, on the deck
of a sea going vessel or in the cargo hull compartment of the vessel. The units
have a protective cover. The units have 4 stacking pins located in each topside
corner that match 4 holes located in the 4 corner feet of the unit so that they can
securely be stacked 2 high during storage.
B Transportation
The DIP 500 can be transported over land using a truck and flatbed trailer capable
of hauling 6000 lb, military air transport or an ocean going vessel with deck space of
8 feet by 16 feet to the scene. The unit has fork lift slots and lifting bridles for
loading and deploying operations.
4 ASSEMBLY AND DEPLOYMENT
A DIP 500 ASSEMBLY
i)
Assemble DIP 500 Unit
(1) Remove the cover from the skimmer