OPERATION ARD TESTING
TESTING:
Test by pushing the test button on the cover. This
will sound the alarm if the electronic circuitry,
alarm, and battery are working. If no alarm
sounds, the unit has defective batteries or other
failures.
DO NOT use an open flame to test your alarm, you
could damage the alarm or ignite combustible
materials and start a structure fire.
NOTE: WEEKLY TESTING IS REQUIRED
Normal Condition
The green LED light is always on and the red LED
should flash every 40 seconds to show that the
alarm is active.
Alarm Condition
When the Alarm senses products of combustion
and sounds the audible alarm, the red LED will
flash one flash/second. The flashing LED and
pulsating alarm will continue until the air is
cleared.
Low Power Pack Condition
IMPORTANT: Your smoke alarm requires the power
pack (9v DC battery) to have sufficient capacity of
power to operate correctly.
Should your smoke alarm enter a low power pack
condition, the unit will emit an audible chirp once
every 40 seconds. When this occurs, you must
replace the battery immediately. Your smoke alarm
will continue to warn of this low power pack
condition for approximately 30 days, however,
failure to change the battery after this time would
mean your smoke alarm may have insufficient
power to alert you in a real fire situation. After the
battery is replaced, the low power warning chirp
will stop.
Faultinc:lication
The alarm chirp occurs every 40 seconds.
Alarm silence
DANGER:
If
your smoke alarm emits the full alarm
signal and you are not testing the unit, the smoke
alarm is warning you of a potentially dangerous
situation that requires your immediate attention.
Only use the alarm silence function after making
sure that there is no ongoing fire emergency
situation. Do not block the vents on the alarm or
disable the smoke alarm in any way, as this will
remove your protection. Smoke alarms can
sometimes react to cooking fumes or other non
emergency situations. In the event of a known false
alarm your smoke alarm can be temporarily
silenced by pressing the test button. Your alarm will
automatically return to full sensitivity within 8
minutes.
NOTE:
1. Press and release the silence button, the alarm
sound will stop.
2. Your alarm will silence and enter into a reduced
sensitivity reset cycle for approximately 8 minutes.
3. During the reduced sensitivity reset cycle, the red
LED will flash once every 8 seconds.
4. Your alarm will automatically return to full
sensitivity on completion of the reset cycle and the
red LED will revert to flashing once every 40
seconds.
DANGER: Never ignore any alarm ignoring the
alarm may result in injury or death.
If
your smoke
alarm activates and alarms and you are not
absolutely certain of the source of the smoke, get
everyone out of the house immediately.
BATTERY REPLACEMENT
The secondary backup power for the smoke alarm
is supplied by a 9V alkaline battery. The battery
should last at least 5 years under normal operating
conditions.
CAUTION: Test the smoke alarm for correct
operation using the test facility whenever the
battery is replaced.
Recommended use the following 9 v batteries for
smoke alarm battery replacement.
Alkaline Battery: Pairdeer 6LR6 l
BATTERY REMOVEAL FINGER SLOT
Dlagram6
WHAT TO DO IN CASE OF A nRE IN
YOURHOME
1. Do not be panic, and stay calm.
2. Alert small children in the home.
3. Leave immediately by your escape plan. Every
second counts, so don't waste time getting dressed
or picking up valuables.
4. In leaving, don't open any inside door without
first feeling its surface.
If
hot, or if you see smoke
seeping through crack don"t open that door!
Instead, use your alternate exit.
If
the inside of the
door is cool, place your shoulder against it, open it
slightly and be ready to slam it shut if heat and
smoke rush in.
5.
If
the air is smoky, stay close to the floor. Breathe
shallowly through a cloth, wet if possible.
6. Once outside, go to your selected meeting place
and make sure everyone is there.
7. Call the fire department from your neighbor's
home -not from yours!
8. Don't return to your home until the fire officials
say that it is all right to do so.
ROUTINE MAINTENANCE
• In addition to weekly testing, the alarm requires
periodic cleaning to remove dust, dirt, and debris.
• Clean the alarm at least once a month to remove
dust, dirt, or debris.
• Use a vacuum cleaner with the soft brush,
vacuum all sides and covers of smoke alarm
device.
• This alarm has a low battery monitor which will
cause the alarm to "chirp" approx every 40
seconds and the red LED flash once at the same
time for a minimum of thirty days when the battery
gets low.
• If
there is a defective battery or other failures, you
can refer to "Trouble shooting" for solution, if there
are still failures during warranty, you can return it
to your retailer.
IMPORTANT: Do not attempt to remove the cover to
clean inside. This will affect warranty.
Cautions:
• Photoelectric smoke detectors can reduce the
likelihood of a disaster, but they cannot guarantee
a 100% safety.
• To ensure your maximum security, please install
all smoke detectors exactly according to this
manual.
• Keep the detectors clean. Do not allow dust to
accumulate and test them at least once a week.
• Replace them immediately if they are not
working properly.
(i)
TROUBLE SHOOTING
Problem
Trouble shooting
I .Remove smoke alarm from
bracket, then check the battery
is properly connected to battery
connector.
Smoke alarm does not 2.If there are still failures during
sound when tested.
warranty, you can return it to
your retailer.
3. If the unit is out of warranty,
please replace it with another
new alarm.
The alarm chirp occurs The battery is in low battery
every about approx 40 status, please replace battery,
seconds, at the same
and refer to "replace battery"
time as the red LED
section.
flash once.
I.Clean smoke alarm. Please
refer to the "maintenance and
Smoke alarm chirp
cleaning" section.
occurs every approx 40 2. Purchase and change another
seconds (alarm goes in- smoke alarm if the problem still
to fault mode).
exists.
I .Press test button to pause
Smoke alarm sounds
alarm.
unwanted alarms
2.Clean smoke alarm device.
intermittently or when Please refer to the "maintenance
residents are cooking, and cleaning" section.
taking showers, etc.
3. Move smoke alarm device to
new location and press test
button.
I .Clean smoke alarm device.
Please refer to the "maintenance
and cleaning" section.
The alarm sounds
2.If there are still failures during
different from it is used warranty, you can return it to
to. It starts and stops.
your retailer.
3. If the unit is out of warranty,
please replace it with another
new alarm.
-
WARRAMTY INFORMATION
Company warrants to the original consumer.
Purchase each new smoke alarm device to be free
from defects in material and workmanship under
normal use and service for a period of 3 years from
the date of purchase. This warranty does not cover
damage resulting from accident, misuse or abuse
or lack of reasonable care of the product. In no
case shall company be liable for any incidental or
consequential damages for breach of this or any
other warranty express or implied, whatsoever.
The bad products can be mailed to the seller and
detail the problem.
MANUFACTURER
Zhejiang Jiaboer Electronic Technology Co., Ltd
Address: NO.606 South Daqiao Road, Dayuan Town,
Fuyang District, Hangzhou City, Zhejiang Province,
China.
E-mail: [email protected]
Tel: + 86-571-63501151
@