Trouble shooting
In case of error, a red light flashes a certain number of times, indicating an error number as shown in
the table below:
If the error persists, contact with JBC technical service.
Features
Fuse
Equipotencial
Connector
Power Socket
Main Switch
Tool Connector
Communications Connector
LED Indicator *
Nº Error
Description
Solution
1 times
Short-circuit
Replace Cartridge
2 times
Open circuit
Replace Cartridge
3 times
Tool not accepted
Check if the tool is compatible with the Contron Box
4 times
Tool detection error
Check the tool
6 times
Current usage leads to overloading
Due to overload wait until the device has cooled down
7 times
Short-circuit
Check if the cartridge is compatible with the Control Box
12 times
Memory error
Reset the Control Box
*LED Indicator:
· Blue: equipment powered
· Green: equipment working
· Red blinking: error. See table
below for more info.
www.jbctools.com