Settings

Program Settings

Edit Program

Edit Program 8

1     Temp unit

                

 Celsius

  

 Maximum temp     450

0

C

3

    Minimum temp         T OFF*

4   Fix temp                    400

0

C

5    Temp Adjust                  0

0

C

6    Max air                        100%
7    Min air                             10%
8    Fix air                             40%
9    Time to stop           120 sec
10  Beep                                     ON
11   Pop up                                 ON
12  Change PIN

1       

 

Programs

2       Edit program

3

       Copy program

4       Delete program

Back

Select

Program

Step 

4

Time 

20

Temp  450
Air 

100

º

C

º

C

8

Exit

Counters

1       Station ON hours  

      

            0

2      Works  hours                                0

3

     Works cycles                      0

Back

Temp 

º

C

º

C

Program 8

380

Air 

100%

Time  125s.

8

9

* Selecting Minimum Temp as 
“T OFF”, the air blows at room 
temperature.

Menu Screen

Original PIN: 0105

Decrease program 

number

Increase program 
number

Selected program

Current temperature

Selected air flow

Graph of selected 

program

Remaining time

Program Mode

Edit Program

This option allows you to edit or create a program. 
First, you must select the program to edit and then modify the points that make up the program. 
Each program is composed of 9 points, each point consisting of 3 parameters: 
 

1. Time (seconds) 

 

2. Temperature (°C / °F) 

 

3. Flow rate (%)

You can delete the last point of the program by selecting “-----” in the time parameter. 
Remember that the regulation range permitted by the station is between 150°C and 450°C, so it is 
not possible to create temperature ramps between room temperature ( T OFF ) and 150°C.

The station can store up to 25 temperature programs.
The first three programs are installed as an example.

Copy Program

This option allows you to copy a program. 
You must select the program source and its destination (where it will be copied).

Delete Program

This option will allow you to delete a previously selected program.

8

www.jbctools.com

9

Содержание TE-1C

Страница 1: ...English www jbctools com Precision Hot Air Station Ref TE C www jbctools com ...

Страница 2: ...Station Ref TE C Precision Heater hose set 1 unit Ref TE TB Stand 1 unit Ref TE SA JTE Control Unit 1 unit Ref JTE 1C JTE 2C JTE 9C Extractor desk 1 unit Ref 0008752 Suction Tube Ref 0932330 Suction Cups Ref 0930110 Ø 10 0934050 x3 Ø 4 7 0934070 x1 Extractors Ref E2184 E2064 E2052 Protectors Ref P2220 P2230 P2235 P4000 P4010 Tripod Ref T2050 T2250 Nozzles Ref TN9209 Ø 3mm TN9208 Ø 4mm TN9080 Ø 5mm...

Страница 3: ...dal to start hot air or release to stop Heating element Precision Heater Hose set Ref TE TB Suction Tube Ref 0932330 For tripods and extractors Activates the suction pump USB B connector Update the station software from the JBC website Suits your work position Adjustable Stand Nozzle Changer Nozzle changer Ref Shape Size TN9209 Straight Ø 3mm TN9208 Straight Ø 4mm TN9080 Straight Ø 5mm TN9787 Bent...

Страница 4: ...We recommend using the protector tripod We recommend using the extractors Protectors Extractors 1 2 3 4 Protectors Ref AxB mm Ref AxB mm P3353 4 3 x 3 48 P2230 15 x 15 P3786 5 2 x 5 2 60 P4010 17 x 17 P3352 5 2 x 7 5 P4005 18 x 29 P3355 5 2 x 9 5 P4030 18 5 x 18 5 P3356 6 2 x 4 2 P1068 18 5 x 24 P3785 7 2 x 7 2 P2685 28 5 x 28 5 P3784 8 2 x 8 2 P4085 31 5 x 31 5 P4035 9 x 13 P2672 33 x 46 P4040 9 ...

Страница 5: ... temperature Selected air flow Graph of selected program Remaining time Program Mode Edit Program This option allows you to edit or create a program First you must select the program to edit and then modify the points that make up the program Each program is composed of 9 points each point consisting of 3 parameters 1 Time seconds 2 Temperature C F 3 Flow rate You can delete the last point of the ...

Страница 6: ...void the needle protruding from the lower part Pick Place Ref T260 A Straight Needles Set Ref 0901546 Bent Needles Set Ref 0861660 10 11 Only perform this operation when the element is cold and the unit is disconnected from the mains 1 Loosen the screw 2 Pull the heating element away from the handle 3 Connect the new heating element ensuring it is pushed all the way in 4 Tighten the screw Replacin...

Страница 7: ... taken with liquid tin waste which can cause burns This appliance can be used by children over the age of eight and also persons with reduced physical sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved Children must not play with the appliance Maintenance mus...

Страница 8: ... Weight 5 2 kg 11 4 lb Dimensions 148 x 184 x 140 Nominal Power 300W Temperature selection Room temperature 150ºC to 450 C 300ºF to 840ºF Cool mode T Off Used to blow air at room temperature Ambient Operating Temperature 10 to 40ºC 50 104ºF Idle Temp Stability 20 ºC 36 ºF Air flow regulation 3 17 SLPM USB connector station PC P 005 Pedal connector Complies with CE standards ESD protected housing s...

Страница 9: ...y does not cover product wear due to use or mis use In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased This product should not be thrown in the garbage In accordance with the European directive 2002 96 EC electronic equipment at the end of their life must be collected and returned to an authorized recycling facility ...

Отзывы: