Fume extractor
Ref. F3435 (for T245 / T470)
Ref. F3450 (for T210)
Cable collector
Ref. CC1001
Keeps the work
area free of cable.
Clips can be easily
removed for quick
maintenance.
Accessories
The Seal is meant to prevent undesirable flux vapors or particles from entering inside the tool. Its
usage is highly recommended for intensive applications when soldering in exposed to FOD environ-
ments or for applications where the soldering iron works close to vertical position.
Replacing Seals
Before replacing the seal, unplug the power supply and make sure the device is not hot.
Note the Seal mounting posi-
tion. The chamfered side has
to be positioned towards the
Handle.
2. Mounting position
3. Inserting the Seal
1. Removing the Seal
Seal
Handle
Gently push the Seal inside
the handle until it is complete-
ly into the Handle.
Handle and Seal edges have
to be aligned.
Enter a small shaft or screw-
driver in order to gently lift
and pull the Seal.
Do not insert the tool more
than 8 mm deep.
Never use a cartridge to do
this operation.
8