Connect the SMR with the supplied AC adapter (1). The DC IN indicator must become lighted
Connect the PC/PLC serial port DB9 male connector to the SMR by using the DB9 cable (2).
Connect two JBC Devices to the SMR by using the M8F-M8M 5V 3M cables (3). Typical devices are the
UCR Control Unit (4) and de SFR Solder Feeder for Robot (5).
Ensure that both device protocol settings are configured as “WITH ADDRESS” and the address of each
devices is different. Default address values is 01 for the UCR and 10 for the SFR.
Installation
LED Indicators
The indicator lights STATION 1, STATION 2, and PC are very useful for debugging communications:
PC Indicator Light
PC indicator (6) blinks every time the PC sends bytes to the stations. If this led doesn’t blink, the port
number assigned to the communication software is incorrect.
Station Indicator Light
STATION1 and STATION2 lights (7) blink when the JBC devices answers a frame to the PC. If these
lights don’t blink, check if the address settings are properly defined.
If the device adress is unknown, JBC recommends to download the
Robot Control Software*
and use
the “Discovery Connected Devise” funktion.
*available at
www.jbctools.com/jbcsoftware.html