1
Reset settings
2 Station settings
3
Tool settings
4 Programs Settings
AP250
AL250
AL250
SF280
SF250
ALE250
AP250
AL250
AL250
SF280
SF250
ALE250
3
4
SF without Guide Tube assembled
Replacing the Guide Tube
Once the tool is disconnected from the control unit follow the instructions below:
Disassemble the outlet nozzle (1) from the guide tube.
Open the guide clamp (2), take off the guide tube (3) and insert the new one.
Note:
The guide tube length can be easily adjusted (4) when the guide clamp knob (2) is open.
Once the guide tube length is adjusted close the guide clamp knob (2).
Assemble the outlet nozzle (1) onto the guide tube tip.
Enter en “Tool Settings” at the SF control unit main menu and select the proper wire diameter.
Guide Clamp
Knob
Guide
Tube
Outlet
Nozzle
SF with Guide Tube assembled
1
Guide
Tube
2
6