manualshive.com logo in svg
background image

350

ºC

Port

2

Power

45%

Temp. Levels

T245

250

350

380

17:14

58

59

Port

2

T245

17:14

350

ºC

Port

2

Power

45%

T245

17:14

Selected 350ºC

Sleep

Tool in the stand
Actual Temp. 180ºC

Delay to hibernation: 29:30

Port

2

T245

17:14

Hibernation

Actual Temp. 25ºC

Station

Tools

Counters

Reset

Graphics

Peripherals

3. Hibernación

Funcionamiento

El exclusivo sistema calefactor de JBC

Nuestra tecnología revolucionaria es capaz de recuperar la temperatura de la punta de forma 
extremadamente rápida. Esto significa que el usuario puede trabajar a una temperatura más baja 
y mejorar la calidad de la soldadura. Esta temperatura se reduce aún más gracias a los modos de 

Sleep

 e 

Hibernation

 que incrementan hasta 5 veces la vida de las puntas.

1. Trabajo

2. Sleep

Al levantar la herramienta 
del soporte, la punta se 
calienta hasta la temperatura 
seleccionada.

Si la herramienta permenece 
en el soporte, la temperatura 
se reduce a 180ºC / 360ºF 
(temperatura predefinida).

Tras largos periodos de 
inactividad (predefinido a 
30min), se corta el suministro 
de energía y la punta se enfría  
hasta temperatura ambiente.

Menú 

Tools

:

· Configure la temperatura  
  de Sleep
· Configure el tiempo de  
  retraso de Sleep  
  (de 0 a 9 min o ninguno)

· Configure el retraso de
  Hibernación  
  (de 0 a 60 min  o ninguno)

Menú 

Tools

:

Menú 

Tools

:

Periodos  
largos en el 
soporte

· Configure límites de   
  temperatura.
· Seleccione niveles de  
  temperatura.

Unidad de memoria USB conectada.

Estación controlada por un PC.

Estación controlada por un robot.

Actualización del software de la estación. 
Pulse INFO para iniciar el proceso.

Aviso. 
Pulse INFO para la descripción del fallo. 

Error. Pulse INFO para la descripción del 
fallo, el tipo de error y cómo proceder. 

Notificaciones (Barra de estado)

Ayuda de la 
estación

Indicador de 
potencia

Herramienta 
en uso

Pantalla de trabajo

Barra de 
estado

La DDE presenta una 

interfaz de usuario intuitiva

 y ofrece un 

rápido acceso 

a los parámetros.

Cambio de 
puerto

Se muestra si 
los niveles de 
temperatura 
están activos

Pulse INFO para la descripción de parámetros.

Opciones de Menú

www.jbctools.com

Содержание RMVE-B

Страница 1: ...Premium Complete Rework station with Pneumatic Pump Ref RMVE B Espa ol 35 English 3 Page www jbctools com...

Страница 2: ...nit MVE Module Features 16 Stands Tip Cleaner 18 T245 Changing Cartridges 20 DR560 Changing Tips 21 DR560 Changing the Heating Element 22 DR560 Tin Deposit Cleaning 23 DR560 Tip Care 24 Desoldering Pr...

Страница 3: ...E Control Unit 1 unit Ref JTE 1C 120V JTE 2C 230V JTE 9C 100V Tip Cleaner 1 unit Ref CL9885 JT Accessory set Ref 0012332 Sponge 1 unit Ref S0354 Metal Brush 1 unit Ref CL6217 Cartridges 2 units Ref C2...

Страница 4: ...005 Ref C560013 Ref C560004 Manual 1 unit Ref 0016198 Premium Complete Rework station with Pneumatic Pump Ref RMVE B Stand Cable 2 units Ref 0011283 Power cords For DDE 1 unit Ref 0013671 100 120V 001...

Страница 5: ...Precision Heater hose set Ref TE TB Power Socket Fuse Equipotential connection To Pedal Ref P 005 Press the pedal to start hot air or release to stop In case of loosely fitting nozzle Ref Shape Size...

Страница 6: ...d using the extractors Protectors Extractors 1 2 3 4 Protectors Ref AxB mm Ref AxB mm P3353 4 3 x 3 48 P2230 15 x 15 P3786 5 2 x 5 2 60 P4010 17 x 17 P3352 5 2 x 7 5 P4005 18 x 29 P3355 5 2 x 9 5 P403...

Страница 7: ...ng time Program mode Program Options Edit Program This option allows you to edit or create a program First you must select the program to edit and then modify the points that make up the program Each...

Страница 8: ...Temp to T OFF allows for blowing at ambient temperature Menu screen Original PIN 0105 Only perform this operation when the element is cold and the unit is disconnected from the mains 1 Loosen the scr...

Страница 9: ...potential connection Power Socket Desoldering Iron Ref DR560 A Cartridge Ref C245903 Ref C245906 Tip Ref C560004 Ref C560005 Ref C560013 Pneumatic Desoldering Module Ref MVE A 16 17 Stand Ref DR SD St...

Страница 10: ...ve cleaning method It leaves a small layer of solder on the tip to prevent oxidation between cleaning and rewetting It prevents splashing of solder particles Also used for sponge or brushes for Sponge...

Страница 11: ...vel Special models Save time and change cartridges safely without switching the station off DR560 Changing Tips This operation should be done while the tip is hot not below 250 C so that any tin left...

Страница 12: ...the cartridge by lining it up to the mark DR560 Tin Deposit Cleaning 1 Removing the lid 3 Inserting the deposit Check filter Lid Check internal joint 2 Cleaning The filter and internal joint must be...

Страница 13: ...remove the solder 3 Aspirating 1 Placing 2 Rotating The intake tube should be periodically cleaned by the largest rod DR560 Tip Care Important DO NOT press the vacuum pump button while tinning the de...

Страница 14: ...om 0 to 9 min or no Sleep Set Hibernation delay from 0 to 60 min or no hibernation Tools Menu Tools Menu Long time in the stand Set temperature limits Select temperature levels 350 C Port 2 Power 45 T...

Страница 15: ...port graphic Soldering Net Remotely manage and monitor as many stations as your PC can handle Functions Set all the station parameters from your PC Organize groups of stations and set all their param...

Страница 16: ...equipment to cool Clean the station screen with a glass cleaner or a damp cloth 1 Pull off the fuse holder and remove the fuse If necessary use a tool to lever it off 2 Press the new fuse into the fus...

Страница 17: ...iance and understand the hazards involved Children must not play with the appliance Maintenance must not be carried out by children unless supervised It is imperative to follow safety guidelines to pr...

Страница 18: ...MVE m dulo Caracter sticas 48 Soportes y limpiador de puntas 50 T245 Cambiar Cartuchos 52 DR560 Cambiar Puntas 53 DR560 Cambiar elemento calefactor 54 DR560 Limpiar dep sito de esta o 55 DR560 Manteni...

Страница 19: ...ion Tube Tubo de succi n Ref 0932330 Suction Cups Ventosas Ref 0930110 10 0934050 x3 4 7 0934070 x1 Extractors Extractores Ref E2184 E2064 E2052 Protectors Protectores Ref P2220 P2230 P2235 P4000 P401...

Страница 20: ...unidad Ref 0965970 Long Tip Cleaning set Juego de limpieza de puntas largo 1 ud Ref 0965760 Tips Puntas 3 unidades Ref C560005 x1 Ref C560013 x1 Ref C560004 x1 Tin deposit Dep sito de esta o 1 u Ref 0...

Страница 21: ...a conectable Precision Heater hose set Conjunto calefactor de precisi n Ref TE TB Entrada de red Fusible Conexi n equipotencial Al Pedal Ref P 005 Con el pedal pulsado se emite aire caliente Para una...

Страница 22: ...extractores Recomendamos usar protector tr pode 1 2 3 4 Protectores Ref AxB mm Ref AxB mm P3353 4 3 x 3 48 P2230 15 x 15 P3786 5 2 x 5 2 60 P4010 17 x 17 P3352 5 2 x 7 5 P4005 18 x 29 P3355 5 2 x 9 5...

Страница 23: ...opci n le permite crear o editar un programa Seleccione un n mero de programa a editar y modifique los puntos en funci n de sus necesidades de trabajo Cada programa se compone de 9 puntos y cada punt...

Страница 24: ...ra permite la emisi n de aire ambiente Pantallas de Men PIN original 0105 Heating Hose Set Conjunto calefactor Ref JT T1A 100V 120V JT T2A 230V Heating Element Elemento calefactor Ref 0014107 230V 001...

Страница 25: ...e Mango aislante t rmico suave Ref T245 C Conector RJ12 para Robot Conector USB B Conexi n equipotencial Toma de correinte Desoldering Iron Desoldador Ref DR560 A Cartridge Cartucho Ref C245903 Ref C2...

Страница 26: ...sponja Ref S0354 No es necesario sujetar la base El m todo de limpieza m s eficaz y menos da ino Mantenga la esponja h meda con agua destilada as evitar el desgaste de la punta Recept culo resistente...

Страница 27: ...jbctools com Redondo Cincel Redondo curvado Bisel Modelos especiales Ahorre tiempo cambiando los cartuchos de forma r pida y segura sin apagar la estaci n DR560 Cambiar puntas Esta operaci n debe rea...

Страница 28: ...ho aline ndolo con la marca DR560 Limpieza del dep sito de esta o 1 Retirar la tapa 3 Insertar el dep sito Compruebe el filtro Tapa Compruebe la junta interna 2 Limpiar El filtro y la junta interna de...

Страница 29: ...n esta o nuevo y repita el proceso de desoldadura Cuando la soldadura se liq e gire la punta con suavidad para que el terminal del componente se suelte Pulse el bot n de la bomba de succi n hasta reti...

Страница 30: ...eratura predefinida Tras largos periodos de inactividad predefinido a 30min se corta el suministro de energ a y la punta se enfr a hasta temperatura ambiente Men Tools Configure la temperatura de Slee...

Страница 31: ...otro puerto Red de soldadura Gestione y monitorice tantas estaciones como soporte su PC Funciones Configure todos los par metros de la estaci n desde su PC Organice grupos de estaciones y configure to...

Страница 32: ...o o almacenar desconecte el equipo y d jelo enfriar 1 Tire del portafusible para retirar el fusible Si lo precisa utilice una peque a palanca 2 Sustituya el fusible y coloque de nuevo el portafusibles...

Страница 33: ...aratodeunamanerasegurayentiendanlosriesgosqueimplica Losni os no deben jugar con el aparato Los ni os no deber n realizar tareas de mantenimiento sin supervisi n Es necesario cumplir estas normas de s...

Страница 34: ...66 67 Exploded View Despiece www jbctools com...

Страница 35: ...pment at the end of their life must be collected and returned to an authorized recycling facility Garant a Esta garant a de 2 a os cubre este equipo contra cualquier defecto de fabricaci n incluyendo...

Отзывы: