Temp
º
C
Air %
Time to stop 45 seconds
Power 70%
400 85
400
º
C Select
12
Operation with JT station
Process Control
3. Releasing
1. Placing
2. Heating
Position the extractor with the
appropriate suction cup and
press the suction button.
Heat the component.
The component lifts off
automatically when the
solder melts.
Access Menu (pess key 2 seconds) & Confirm Selection
Selected temperature
Current temperature
% Instant power supplied
to heater
You can switch between operating modes (Manual Mode / Program Mode) by pressing the
“increase” and “decrease” keys simultaneously for 2 seconds (Only when programs mode is ON).
Manual Mode
Current air flow