manualshive.com logo in svg
background image

Premium   

Complete  Rework  Station 

with  Electric  Pump

Ref.  RMSE-C

Español 

35

English 

3

 

Page

www.jbctools.com

Содержание RMSE-C

Страница 1: ...Premium Complete Rework Station with Electric Pump Ref RMSE C Español 35 English 3 Page www jbctools com ...

Страница 2: ...Control Unit MSE Module Features 16 Stands Tip Cleaner 18 T245 Changing Cartridges 20 DR560 Changing Tips 21 DR560 Changing the Heating Element 22 DR560 Tin Deposit Cleaning 23 DR560 Tip Care 24 Desoldering Process DDE MSE 24 MSE Initial Setup 25 MSE Changing the pump filters 25 Operation with DDE 26 Process Analysis 28 Soldering Net 29 Working with robots 30 Station Sotware 30 Maintenance 31 Safe...

Страница 3: ...Unit 1 unit Ref DDE 1B 120V DDE 2B 230V DDE 9B 100V Desoldering Iron 1 unit Ref DR560 A C560003 already inserted Stand 1 unit Ref DR SD General Purpose Handle 1 unit Ref T245 A Heater hose set 1 unit Ref JT T1A 100V 120V JT T2A 230V Stand 1 unit Ref JT SD JTE Control Unit 1 unit Ref JTE 1D 120V JTE 2D 230V JTE 9D 100V www jbctools com ...

Страница 4: ...C245906 These accessories are not supplied with JT 2QC JT 1QC JT 9QC stations Extractor stand 1 unit Ref 0008752 Suction Tube Ref 0932330 Suction Cups Ref 0930110 Ø 10 0934050 x3 Ø 4 7 0934070 x1 Extractors Ref E2184 E2064 E2052 Protectors Ref P2220 P2230 P2235 P4000 P4010 Tripod Ref T2050 Ø 39mm T2250 Ø 85mm Nozzles Ref JN2015 x1 JN2012 x1 JN2020 x1 ...

Страница 5: ... Accessories Ref 0010211 Internal gasket 2 units Ref 0812360 Tip cleaning set 1 unit Ref 0965970 Spanner 1 unit Ref 0780550 Tin deposit 1 unit Ref 0812620 Long Tip Cleaning set 1 unit Ref 0965760 Metal tin diposit 1 unit Ref 0812630 Tips 3 units Ref C560005 Ref C560013 Ref C560004 Filter Box 1 unit Ref 0780840 It contains 10 filters www jbctools com ...

Страница 6: ...E 1 unit Ref 0013671 100 120V 0010569 230V Module Cable 1 unit Ref 0014874 Cleaning stick 1 unit Ref 0786640 Pick Place 1 unit Ref T260 A Straight Needles Set 1 unit Ref 0901546 Bent Needles Set 1 unit Ref 0861660 Cups Set 1 unit Ref 0940163 Union Flanges 1 unit Ref 0011356 For JTE 1 unit Ref 0009417 100V 120V 0009401 230V www jbctools com ...

Страница 7: ...ket Optional P 005 Pedal connection Fuse Equipotential connection Heating element Suction Tube Ref 0932330 Heater Hose set Ref JT T1A 100V 120V JT T2A 230V Stand Ref JT SD For tripods and extractors Activates the suction pump USB B connector Update the station software from the JBC website www jbctools com ...

Страница 8: ...d Stand Autostart OFF Stand Autostart ON Pedal Adjust the tool holder angle to suit your work position Press the start stop button to blow hot air The tool will start blowing hot air when it is lifted from the stand Press the Pedal to blow hot air and release to stop The P 005 Pedal is not supplied with this station See our website Adjustable Stand Operation Modes ...

Страница 9: ...pe Size JN2020 Straight Ø 8mm JN8417 Straight Ø 10mm JN2015 Bent Ø 4mm JN2012 Bent Ø 6mm JN6633 Bent Ø 8mm JN7637 Flat 10 x 2mm JN7638 Flat 20 x 2mm JN7639 Flat 30 x 2mm Straight Bent Flat Ø mm Ø mm A x B mm 1 Push the nozzle tab inwards with a screwdriver or flat nosed pliers 2 Insert the nozzle into the JT TA Heater again Turn the tool off and handle with care The heating element and the nozzle ...

Страница 10: ...5 x 24 P3785 7 2 x 7 2 P2685 28 5 x 28 5 P3784 8 2 x 8 2 P4085 31 5 x 31 5 P4035 9 x 13 P2672 33 x 46 P4040 9 5 x 19 P4002 50 x 50 P4080 9 5 x 21 P3357 52 5 x 14 32 P2220 10 x 10 P4045 10 5 x 21 P4090 11 x 16 24 P2235 12 x 17 P1249 12 x 23 44 P4000 12 5 x 12 5 P3354 13 2 x 13 2 P4025 13 5 x 21 5 øD Reference Desk Tripods Ref øC mm T2050 39 T2250 85 Manual extractor Ref øD mm E2190 7 Extractors Ref...

Страница 11: ...on T260 Pick Place Press the button to start stop the suction Once activated the suction button cover the pen hole with your finger and pick the component Insert the needle with the appropriate cup for a correct suction process Lift your finger to release the component on the appropriate place You should avoid the needle to stick out of the lower part Operation Pick Place Ref T260 A www jbctools c...

Страница 12: ... suction button Heat the component The component lifts off automatically when the solder melts Access Menu pess key 2 seconds Confirm Selection Selected temperature Current temperature Instant power supplied to heater You can switch between operating modes Manual Mode Program Mode by pressing the increase and decrease keys simultaneously for 2 seconds Only when programs mode is ON Manual Mode Curr...

Страница 13: ...Time seconds 2 Temperature C F 3 Flow rate You can delete the last point of the program by selecting in the time parameter It should be taken into account that the regulation range permitted by the station is 150 450 C whe reby it is not possible to create temperature ramps between room temperature Toff and 150 C The station can store up to 25 temperature programs The first three programs are edit...

Страница 14: ...p Adjust 00 C 6 Max air 100 7 Min air 10 8 Fix air 1 Programs OFF 2 Edit program 3 Copy program 4 Delete program Back Select Program Step 1 Time 30 Temp 300 Air 100 ºC ºC 1 Exit Counters 1 Station ON hours 0 2 Works hours 0 3 Works cycles 0 Back 9 Time to stop 120 sec 10 Stand Pedal Stand Autostart OFF 11 Beep ON 12 Pop up ON 13 Change PIN 14 Selecting Minimum Temp as T OFF the air blows at room t...

Страница 15: ...Tighten the screw JT TA Replacing the Heating Element Heating Hose Set Ref JT T1A 100V 120V JT T2A 230V Heating Element Ref 0014107 230V 0014105 100V 120V Handle Ref JT A 1 Ensure that the tool is turned off 2 Use a spanner to unscrew the connecting nut 3 The tube end of the new heater must be inserted so that the longitudinal rib fits into the groove 5 Follow the same steps conversely JT TA Chang...

Страница 16: ...ols and join each station port with 1 module 1 pedal Peripherals Stand Ref AD SD General Purpose Handle Ref T245 A RJ12 connector for Robot USB B connector Equipotential connection Power Socket Desoldering Iron Ref DR560 A Cartridge Ref C245903 Ref C245906 Tip Ref C560004 Ref C560005 Ref C560013 ...

Страница 17: ... Filter Ref 0821830 Module Cable Ref 0014874 USB A connector 2 8 Color TFT screen Tilt the display for easy reading Electric Desoldering Module Ref MSE A To another peripheral To Pedal Ref P 005 www jbctools com ...

Страница 18: ...g cartridges without interrupting your work Adjustable tool holder Suits your work position Adjustable cable collector Adjustable Stands Stand Ref DR SD Quick tip changer Holding tip system for easy change Cable collector Keeps working area free of cable ...

Страница 19: ... prevent oxidation between cleaning and rewetting It prevents splashing of solder particles when using the brass wool Heavy weighted non slip base for simple handed cleaning The least harmful cleaning method Keep the sponge damp with distilled water when working to avoid tip wear A temperature resistant receptacle lets the operator remove excess solder by gentle tapping or wiping It can be easily ...

Страница 20: ...e as follows A For straight C210 B For curved C210 C For curved C245 D For straight C245 Important It is essential to insert the cartridges as far as the mark for a proper connection B C A D Compatible cartridges The T245 handle works with C245 cartridges Find the model that best suits your soldering needs in www jbctools com Round Chisel Round bent Bevel Special models Save time and change cartri...

Страница 21: ... 8 Ømax pin 0 6 C560 003 ØA 2 7 ØB 1 Ømax pin 0 8 C560 004 ØA 3 2 ØB 1 3 Ømax pin 1 1 C560 009 ØA 5 ØB 1 3 Ømax pin 1 1 C560 014 ØA 2 5 ØB 0 8 Ømax pin 0 6 1 Removing Unscrew the tip using the spanner supplied 2 Inserting Fit the new tip and tighten with the spanner to make sure it is air tight Compatible Tips The DR560 works with C560 tips Find the model that best suits your soldering needs in ww...

Страница 22: ...sen the screw as shown and remove the Heating Element 3 Placing Place the new Heating Element and follow the steps conversely 2 1 3 To perform this operation turn off the station or disconnect the tool Important For a proper connection it is essential to insert the cartridge by lining it up to the mark ...

Страница 23: ...ecked and replaced if dirty or damaged Remove the coil to clean the inside of the deposit with the stick supplied The lid must be removed with the DR560 in vertical position The deposit must be inserted with coil filter in place positioned between the 2 lines marked on the tin deposit Then the whole unit must be closed by screwing the lid Marks www jbctools com ...

Страница 24: ...mains are left on a terminal after desoldering it resolder it with fresh solder and repeat the desoldering operation When the solder liquefies gently rotate the tip so that the compo nent terminal can be lifted off Press the vacuum pump button long enough to remove the solder 3 Aspirating 1 Placing 2 Rotating The intake tube should be periodically cleaned by the largest rod DR560 Tip Care Importan...

Страница 25: ...n filter Ref 0821830 O Ring Ref 0007717 Filter cover Ref 0004710 Important Do not use sharp pointed objects to open the suction filter 1 Select the module from the list of peripheral connections Remember your first connection is denoted as a the second being b etc e g MSE_a MSE_b 2 Press Menu or Back to save changes Once set up you can change the module settings by entering the Peripherals Menu MS...

Страница 26: ...tip will heat up to the selected temperature When the tool is in the stand the temperature falls to the preset Sleep temperature After longer periods of inactivity the power is cut off and the tool cools down to room temperature Tools Menu Set Sleep temperature Set Sleep delay from 0 to 9 min or no Sleep Set Hibernation delay from 0 to 60 min or no hibernation Tools Menu Tools Menu Long time in th...

Страница 27: ...Error Press INFO for failure description the type of error and how to proceed System notifications Status Bar Menu Options Station Information Power indicator Tool in use Work Screen Status bar The DDE offers an intuitive user interface which provides quick access to station parameters Change port Displayed if temperature levels are activated Station Tools Counters Reset Graphics Peripherals Press...

Страница 28: ... and power figures in real time are displayed for each port This helps you decide which tip to use to obtain the best quality solder joints Process analysis Export graphics Insert a USB flash drive into the USB A connector to save your soldering process in csv format Graphics Temperature Power See other port graphic ...

Страница 29: ...me Store specific configurations for later uses Analyze the soldering graphics of the stations on your PC and export them 1 Download the JBC Manager software and the user manual from www jbctools com manager html 2 Connect the stations via USB B connector and the PC will automatically detect them 3 The notification will be displayed on the station any JBC station JBC Manager software USB Hub www j...

Страница 30: ...mands according to the Robot Communication Protocol available on the website www jbctools com jbcsoftware menu 115 html Manage and monitor the station using a Robotic system Working with Robots Control Unit Robot Update the station software 1 Download the JBC Update File from www jbctools com software html and save it on a USB flash drive Preferably one with no other files JBC Update File CHB A Co...

Страница 31: ...Alcohol can only be used to clean the metal parts Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status Fuse holder Fuse holder Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder joint Periodically check all cables and tubes Fuse Replace a...

Страница 32: ... can cause inflamable products to ignite Avoid flux coming into contact with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriate protection glasses and gloves when working to avoid personal harm Utmost care must be taken with liquid tin waste which can cause burns This appliance can be used by children over the ag...

Страница 33: ...0ºC 50 104ºF Air flow regulation 10 50 SLPM Vacuum 30 228 mmHg 9 inHg USB connector station PC P 005 Pedal Connection DDE 1B 120V 50 60Hz Input fuse 4A Output 23 5V DDE 2B 230V 50 60Hz Input fuse 2A Output 23 5V DDE 9B 100V 50 60Hz Input fuse 5A Output 23 5V Weight 4 3 Kg 9 3 lb Dimensions 148 x 120 x 232 mm Output Peak Power 150W per tool Temperature Range 90 450 C 190 840 ºF Idle Temp Stability ...

Страница 34: ...y MSE módulo Características 48 Soportes 50 Limpiador de Puntas 51 T245 Cambiar Cartuchos 52 DR560 Cambiar Puntas 53 DR560 Cambiar elemento calefactor 54 DR560 Limpiar depósito de estaño 55 DR560 Mantenimiento de las puntas 56 Desoldar con la DDE y el MSE 56 MSE Puesta en marcha 57 MSE Cambiar los filtros 57 Funcionamiento 58 Pantalla de trabajo 59 Análisis del proceso 60 Red de Soldadura 61 Traba...

Страница 35: ...dad Ref JT SD JTE Control Unit Unidad de Control JTE 1 ud Ref JTE 1D 120V JTE 2D 230V JTE 9D 100V Electric Desoldering Module Módulo desoldador eléctrico 1 unidad Ref MSE A DDE Control Unit Unidad de Control DDE 1 ud Ref DDE 1B 120V DDE 2B 230V DDE 9B 100V General Purpose Handle Mango para aplicaciones generales 1 unidad Ref T245 A Composición Los siguientes artículos deberían estar incluidos www ...

Страница 36: ...uction Tube Tubo de succión Ref 0932330 Suction Cups Ventosas Ref 0930110 Ø 10 0934050 x3 Ø 4 7 0934070 x1 Extractors Extractores Ref E2184 E2064 E2052 Protectors Protectores Ref P2220 P2230 P2235 P4000 P4010 Tripod Tripode Ref T2050 Ø 39mm T2250 Ø 85mm Nozzles Boquillas Ref JN2015 x1 JN2012 x1 JN2020 x1 Tip Cleaner Limpiador de puntas 1 ud Ref CL9885 Metal Brush Cepillo metálico 1 unidad Ref CL62...

Страница 37: ...año 1 ud Ref 0812620 Spanner Llave 1 unidad Ref 0780550 Filter Box Caja de filtros 1 unidad Ref 0780840 Contiene 10 filtros Internal gasket Casquillo junta interior 2 unidades Ref 0812360 Metal tin diposit Depósito de metal para estaño 1 unidad Ref 0812630 Cotton Filter Filtros de algodón 1 unidad Ref 0781046 Contiene 10 filtros Filter Box Caja de filtros 1 unidad Ref 0005966 Contiene 50 filtros S...

Страница 38: ...ectas 1 unidad Ref 0901546 Bent Needles Set Conjunto de agujas dobladas 1 unidad Ref 0861660 Suction Cup Set Conjunto de ventosas 1 ud Ref 0940163 Premium Complete Rework Station with Electric Pump Ref RMSE C Para JTE 1 unidad Ref 0009417 100V 120V 0009401 230V Stand Cable Cable del soporte 2 uds Ref 0011283 Module Cable Cable del módulo 1 unidad Ref 0014874 Union Flanges Bridas de unión 1 unidad ...

Страница 39: ...Activación de la bomba de succión USB B connector Actualice el software de la estación en www jbctools com Interruptor para aire caliente ON OFF Otra herramienta conectable Precision Heater hose set Conjunto calefactor de precisión Ref TE TB Entrada de red Fusible Conexión equipotencial Pedal Ref P 005 Con el pedal pulsado se emite aire caliente Soporte Ref JT SD www jbctools com ...

Страница 40: ... en el soporte Soporte Autostart OFF Soporte Autostart ON Pedal El elemento ajustable del soporte se adapta a su posición de trabajo Pulse el interruptor para emitir aire caliente La herramienta se activa automáticamente cuando se levanta del soporte Use el pedal para el control del calefactor El pedal P 005 no se incluye en esta estación Consulte nuestra web Soporte ajustable Modos de operación ...

Страница 41: ...engüeta hacia dentro con la ayuda de un destornillador o unos alicates planos 2 Inserte la boquilla en el conjunto calefactor Apague la herramienta y maneje con cuidado El elemento calefactor y la boquilla todavía están calientes Ref Forma Medida JN2020 Recta Ø 8mm JN8417 Recta Ø 10mm JN2015 Doblada Ø 4mm JN2012 Doblada Ø 6mm JN6633 Doblada Ø 8mm JN7637 Plana 10 x 2mm JN7638 Plana 20 x 2mm JN7639 ...

Страница 42: ... 7 2 x 7 2 P2685 28 5 x 28 5 P3784 8 2 x 8 2 P4085 31 5 x 31 5 P4035 9 x 13 P2672 33 x 46 P4040 9 5 x 19 P4002 50 x 50 P4080 9 5 x 21 P3357 52 5 x 14 32 P2220 10 x 10 P4045 10 5 x 21 P4090 11 x 16 24 P2235 12 x 17 P1249 12 x 23 44 P4000 12 5 x 12 5 P3354 13 2 x 13 2 P4025 13 5 x 21 5 øD Referencia del soporte de extractores Tripodes Ref øC mm T2050 39 T2250 85 Extractor manual Ref øD mm E2190 7 Ex...

Страница 43: ...e la aguja sobresalga de la parte inferior de la ventosa Esta herramienta permite colocar y retirar SMDs fácilmente gracias al sistema de succión de la unidad 1 Succionar Funcionamiento 2 Soltar Una vez activado el botón de succión cubra el agujero del lápiz con el dedo hasta y recoja el componente Levante el dedo del agujero para soltar el componente en el sitio adecuado Pick Place Lápiz posicion...

Страница 44: ...cte aire caliente con el conjunto calefactor El componente se levantará automáticamente cuando el estaño se derrita Confirme la selección Para acceder al Menú apriete 2 segundos Temperaturaseleccionada Temperatura actual potencia Puede intercambiar los modos manual programa apretando las teclas aumentar o disminuir simultáneamente durante 2 segundos sólo si el modo programa está activo Modo manual...

Страница 45: ...ltimo punto del programa seleccionando en el parámetro Tiempo Tenga en cuenta que el rango de temperatura permitido por la estación es 150 450 C por lo que no es posible crear rampas de temperatura entre la temperatura ambiente y los 150 C La estación puede almacenar hasta 25 programas de temperatura Los primeros 3 programas que muestra la estación han sido editados por JBC a modo de ejemplo Copy ...

Страница 46: ... C 5 Temp Adjust 00 C 6 Max air 100 7 Min air 10 8 Fix air 40 9 Time to stop 120 sec 10 Beep ON 11 Pop up ON 12 Change PIN 1 Programs 2 Edit program 3 Copy program 4 Delete program Back Select Program Step 4 Time 20 Temp 450 Air 100 ºC ºC 8 Exit Counters 1 Station ON hours 0 2 Works hours 0 3 Works cycles 0 Back 46 Seleccionando T OFF en la Mínima temperatura permite la emisión de aire ambiente Pa...

Страница 47: ...l elemento calefactor y sáquelo del mango 3 Conecte el nuevo elemento calefactor hasta que encaje lo más adentro posible 4 Atornille de nuevo JT TA Reemplazar el elemento calefactor JT Handle Manguera JT A Ref JT A 1 Apague la herramienta 2 Desenrosque la tuerca de conexión con la ayuda de una llave inglesa 3 Encaje el extremo del nuevo conjunto calefactor en la unidad de control 4 Siga los mismos...

Страница 48: ... SD Conector RJ12 para Robot Conector USB B Conexión equipotencial Toma de correinte Desoldering Iron Desoldador Ref DR560 A Cartridge Cartucho Ref C245903 Ref C245906 Tip Punta Ref C560004 Ref C560005 Ref C560013 Stand Soporte Ref DR SD Stand Cable Cable del soporte Ref 0011283 General Purpose Handle Mango para aplicaciones generales Ref T245 A ...

Страница 49: ...eléctrico Ref MSE A 49 A otro periférico Al Pedal Ref P 005 Conector USB A Pantalla color TFT de 2 8 Incline la pantalla para una mejor lectura Suction Filter Filtro de succión Ref 0821830 Module Cable Cable del módulo Ref 0014874 www jbctools com ...

Страница 50: ...de herramienta ajustable Se adapta a su posición de trabajo Recogecable ajustable Soportes ajustables Stand Soporte Ref DR SD Cambio rápido de puntas El sistema de sujeción de puntas facilita el cambio Recogecable Mantiene el área de trabajo ordenada sin cable Stand Soporte Ref AD SD ...

Страница 51: ...adura Para esponja Para cepillos Golpeteo Limpieza Mantenimiento Golpe suave para retirar restos de soldadura Ranuras para retirar partículas adheridas Base antideslizante Sponge Esponja Ref S0354 No es necesario sujetar la base El método de limpieza más eficaz y menos dañino Mantenga la esponja húmeda con agua destilada así evitará el desgaste de la punta Receptáculo resistente a la temperatura p...

Страница 52: ...a los C210 rectos B Para los C210 curvados C Para los C245 curvados D Para los C245 rectos Importante Es necesario insertar el cartucho hasta la marca para una conexión correcta Marca Cartuchos compatibles El mango para soldador T245 funciona con cartuchos C245 Encuentre el modelo que mejor se adapte a sus necesidades de soldadura en www jbctools com Redondo Cincel Redondo curvado Bisel Modelos es...

Страница 53: ...C560 003 ØA 2 7 ØB 1 Ømax pin 0 8 C560 004 ØA 3 2 ØB 1 3 Ømax pin 1 1 C560 009 ØA 5 ØB 1 3 Ømax pin 1 1 C560 014 ØA 2 5 ØB 0 8 Ømax pin 0 6 1 Retirar Desenrosque la punta utilizando la llave suministrada 2 Insertar Coloque la punta nueva y enrósquela con la llave para asegurarse que queda hermético Puntas compatibles El DR560 funciona con puntas C560 Encuentre el modelo que mejor se adapte a sus n...

Страница 54: ...llo y retire el elemento calefactor 3 Colocar Coloque el nuevo elemento calefactor hasta la marca y siga los mismos pasos a la inversa 2 1 3 Para realizar esta operación apague la estación o desconecte la herramienta Importante Para una conexión apropiada es necesario insertar el cartucho alineándolo con la marca ...

Страница 55: ...rse para reemplazarlos si fuera necesario ya sea por exceso de suciedad o por algún daño Retire el espiral para limpiar el interior del depósito con la baqueta suministrada La tapa se debe retirar con el desoldador en posición vertical El depósito se debe insertar con el espiral ya colocado entre las dos marcas Concluya el proceso cerrando el depósito con la tapa Marcas www jbctools com ...

Страница 56: ...ura en algun terminal después de desoldarlo vuelva a soldarlo con estaño nuevo y repita el proceso de desoldadura Cuando la soldadura se liqüe gire la punta con suavidad para que el terminal del componente se suelte Pulse el botón de la bomba de succión hasta retirar por completo los restos de soldadura 3 Aspirar 1 Colocar 2 Rotar El conducto de entrada se debe limpiar periódicamente con la baquet...

Страница 57: ...os cables y tubos Mantenga los filtros limpios para garantizar una correcta aspiración y reemplácelos si fuera necesario 1 Seleccione el módulo del listado de conexiones periféricas Recuerde que su primera conexión se indica como a la segunda como b etc MSE_a MSE_b 2 Pulse Menu o Back para guardar los cambios Una vez configurado podrá modificar cambios desde el menú Peripherals Puesta en marcha de...

Страница 58: ... a los modos de Sleep e Hibernation que incrementan hasta 5 veces la vida de las puntas 1 Trabajo 2 Sleep Al levantar la herramienta del soporte la punta se calienta hasta la temperatura seleccionada Si la herramienta permenece en el soporte la temperatura se reduce a la temperatura predefinida Tras largos períodos de inactividad predefinido a 30min se corta el suministro de energía y la punta se ...

Страница 59: ...se INFO para la descripción del fallo Error Pulse INFO para la descripción del fallo el tipo de error y cómo proceder Notificaciones Barra de estado Ayuda de la estación Indicador de potencia Herramienta en uso Pantalla de trabajo Barra de estado La DDE B presenta una interfaz de usuario intuitiva y ofrece un rápido acceso a los parámetros Cambio de puerto Se muestra si los niveles de temperatura ...

Страница 60: ...puestas de temperatura y potencia en tiempo real de cada puerto Esto le ayudará a decidir cuál es la punta más adecuada para obtener la mejor calidad en sus soldaduras Análisis del proceso Exporte gráficos Inserte una unidad de memoria USB para guardar su proceso de trabajo en formato csv Temperatura Potencia Vea el gráfico del otro puerto ...

Страница 61: ...e configuraciones específicas para usos posteriores Analice gráficos del proceso de soldadura de las estaciones desde su PC y expórtelos cualquier estación JBC JBC Manager software USB Hub 1 Descargue el software JBC Manager y el manual de usuario de www jbctools com manager html 2 Conecte las estaciones a través del conector USB B y el PC las detectará automáticamente 3 La notificación se mostrar...

Страница 62: ...nicación para Robots que encontrará en www jbctools com jbcsoftware menu 115 html Gestione y monitorice la estación por medio de un sistema robotizado Trabajar con Robots Unidad de Control Robot Actualice el software de la estación 1 Descargue el archivo de actualización de www jbctools com software html cuando esté disponible y guárdelo en una unidad de memoria USB preferentemente una sin otros a...

Страница 63: ...be periódicamente que las partes metálicas de la herramienta y del soporte están limpias Así la estación puede detectar el estado de la herramienta y activar los modos de Sleep o Hibernation Portafusible Portafusible Mantenga la punta limpia y estañada la para evitar su oxidación Las superfícies sucias reducen la transferencia térmica a la soldadura Revise periódicamente los tubos y cables Fusible...

Страница 64: ...usar que los productos inflamables se enciendan Evite el contacto del Flux con la piel o los ojos para prevenir la irritación Tenga cuidado con el humo producido al trabajar Mantenga su lugar de trabajo limpio y ordenado Use gafas y guantes de protección adecuados Así evitará cualquier daño Tenga cuidado con los restos de estaño líquido En contacto con la piel puede causar quemaduras Este aparato ...

Страница 65: ...0 228 mmHg 9 inHg Conexión USB estación PC Conector para pedal P 005 DDE 1B 120V 50 60Hz Fusible de entrada 4A Salida 23 5V DDE 2B 230V 50 60Hz Fusible de entrada 2A Salida 23 5V DDE 9B 100V 50 60Hz Fusible de entrada 5A Salida 23 5V Peso 4 3 Kg 9 3 lb Dimensiones 148 x 120 x 232 mm Potencia máxima de pico 150W por herramienta Rango de temperatura 90 450 C 190 840 ºF Estabilidad de temperatura en ...

Страница 66: ...66 Exploded View Despiece ...

Страница 67: ...67 www jbctools com ...

Страница 68: ... at the end of their life must be collected and returned to an authorized recycling facility Garantía Esta garantía de 2 años cubre este equipo contra cualquier defecto de fabricación incluyendo la sustitución de partes defectuosas y mano de obra La garantía no cubre el desgaste del producto por uso o mal uso Para que esta garantía sea válida el equipo debe ser devuelto a portes pagados al distrib...

Отзывы: