Recommendations
Parameter description
Warnings
Hibernation Delay
Set the time the tool will
remain at Sleep temperature
before entering the
Hibernation mode. The power
supply is cut off and the tip
remains at room temperature.
Increasing the default
value will accelerate
oxidation and shorten the
tip life.
When you change
the cartridge type, the
parameter should be reset
to 0°C/F or to the value
needed for this cartridge.
E.g. If a correction of
+20°C (+36°F) is set for the
you change the cartridge for
a C245030 (which is thinner)
without resetting, they would
be working at a temperature
of +20°C (+36°F) lower for
the C245030.
Protects the tip from oxidation
during long periods of
inactivity while the tool is in the
stand. Retinning the tip before
placing the tool in the stand
helps prevent oxidation and
extends the life of the tip.
Temp Adjustment
It provides a more precise
adjustment between the
selected temperature and the
actual one.
Set values within ±50°C
(± 90°F) to achieve zero error.
JBC strongly recommends
the use of TID-A or TIA-A
Thermometers to obtain
precise readings.
Fix one temperature
Fix a value within the
temperature range of the
station (90 - 450ºC /
190 - 840ºF).
Ideal for soldering more than
one component at a specific
temperature. The station will
reject any attempt to change
the temperature.
N/a
Change password
Change the default security
password number (0105).
The password must be
entered every time a
parameter is changed.
N/a
www.jbctools.com
9