background image

Temp 

º

C

Temp 

º

C

Air %

º

C

     Time to stop      45 seconds

Profile 8

Power       70%

400

380

80

400

º

C Select

Air 

100%

Time  125s.

6

Decrease & 
move down

Decrease profile 

number

Increase & move up

Increase profile 
number

Access Menu

(pess key 2 

seconds)

&

Confirm Selection

Access Menu

(pess key 2 

seconds)

Selected temperature

Current temperature

% Instant power supplied 
to heater

Selected profile

Current temperature

Selected flow

Graph of selected 

profile

Remaining time

You can switch between operating modes (Manual Mode / Profile Mode) by pressing the “increase” 
and “decrease” keys simultaneously for 2 seconds. (Only if mode profiles is ON)

Process Control

Manual Mode

Profile Mode

Содержание JT-B

Страница 1: ...www jbctools com Hot Air Station Ref JT B www jbctools com...

Страница 2: ...Unit Ref JTE 1B JTE 2B JTE 9B Extractor stand Ref 0008752 Suction Tube Ref 0932330 Suction Cups Ref 0930110 10 0934050 x3 4 7 0934070 x1 Power Cord Ref 0009417 100V 120V 0009401 230V Extractors Ref E2...

Страница 3: ...Create graphs Manage parameters via PC Connectable tools JT T2A JT T1A Heater hose set TE TB Precision Heater hose set Heating element Hot Air switch ON OFF Suction Tube Main switch Heater inlet Vacu...

Страница 4: ...n the nozzle tab with a screwdriver or flat nosed pliers Ref Shape Size JN2020 Straight 8mm JN8417 Straight 10mm JN2015 Bent 4mm JN2012 Bent 6mm JN6633 Bent 8mm JN7637 Flat 10 x 2mm JN7638 Flat 20 x 2...

Страница 5: ...P3784 8 2 x 8 2 P4085 31 5 x 31 5 P4035 9 x 13 P2672 33 x 46 P4040 9 5 x 19 P4002 50 x 50 P4080 9 5 x 21 P3357 52 5 x 14 32 P2220 10 x 10 P4045 10 5 x 21 P4090 11 x 16 24 P2235 12 x 17 P1249 12 x 23...

Страница 6: ...Confirm Selection Access Menu pess key 2 seconds Selected temperature Current temperature Instant power supplied to heater Selected profile Current temperature Selected flow Graph of selected profile...

Страница 7: ...Fix temp 4000 C 5 Max air 100 6 Min air 10 7 Fix air 40 8 Time to stop 120 sec 9 Beep ON 10 Pop up ON 11 Change PIN 1 Profiles 2 Edit Profile 3 Copy profile Back Select Profile Step 4 Time 20 Temp 45...

Страница 8: ...y selecting in the time parameter It should be taken into account that the regulation range permitted by the station is between 150 C and 450 C whereby it is not possible to create temperature ramps b...

Страница 9: ...heating element ensuring its seated all the way in 4 Replace screw 3 Pull back the connecting nut 4 Tube end must be inserted positioned so that the longitudinal rib can fit into the groove 5 Follow...

Страница 10: ...to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder joint Periodically check all cables and tubes connections Replace the fuse if it is blown according to the following...

Страница 11: ...lation grills Heat can cause inflamable products to ignite even when out of sight Use a non residue classified flux and avoid contact with skin or eyes to prevent irritation Be careful with the fumes...

Страница 12: ...ace station PC Complies with CE standards ESD protected housing skin effect Technical Specifications Warranty JBC s 2 year warranty covers this equipment against all manufacturing defects including th...

Отзывы: