Temp
º
C
Air %
Time to stop 45 seconds
Power 70%
400 85
400
º
C Select
For small components
(fig. 1 and 2).
For large components
(fig. 3 and 4).
Operation
Process Control
3. Releasing
1. Placing
2. Heating
6
7
We recommend using the pro tripod
We recommend using the extractors
Protectors & Extractors
1
2
3
4
Protectors
* Ref. AxB (mm)
* Ref. AxB (mm)
P3353 4,3 x 3
48
P2230 15 x 15
P3786 5,2 x 5,2
60
P4010 17 x 17
P3352 5,2 x 7,5
P4005 18 x 29
P3355 5,2 x 9,5
P4030 18,5 x 18,5
P3356 6,2 x 4,2
P1068 18,5 x 24
P3785 7,2 x 7,2
P2685 28,5 x 28,5
P3784 8,2 x 8,2
P4085 31,5 x 31,5
P4035 9 x 13
P2672 33 x 46
P4040 9,5 x 19
P4002 50 x 50
P4080 9,5 x 21
P3357 52,5 x 14
32
P2220 10 x 10
P4045 10,5 x 21
P4090 11 x 16
24
P2235 12 x 17
P1249 12 x 23
44
P4000 12,5 x 12,5
P3354 13,2 x 13,2
P4025 13,5 x 21,5
øD
* Reference Desk
Tripods
* Ref. øC (mm)
T2050 39
T2250 85
Manual extractor
* Ref. øD (mm)
E2190 7
Extractors
* Ref. AxB (mm)
* Ref. AxB (mm)
52 E2052 20 X 20
E2124 45 X 45
64 E2064 20 X 26
80 E2184 24 X 24
E2068 27 X 27
E4020 28,5 X 28,5
E4015 31,5 X 31,5
E2084 33 X 33
E2100 38 X 38
Position the extractor with the
appropriate suction cup and
press the suction button.
Heat the component.
The component lifts off
automatically when the
solder melts.
Access Menu (pess key 2 seconds) & Confirm Selection
Selected temperature
Current temperature
% Instant power supplied
to heater
You can switch between operating modes (Manual Mode / Program Mode) by pressing the
“increase” and “decrease” keys simultaneously for 2 seconds (Only when programs mode is ON).
Manual Mode
Current air flow
6
www.jbctools.com
7