manualshive.com logo in svg
background image

Safety

  It is imperative to follow safety guidelines to prevent electric  
  shock, injury, fire or explosion. 

- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire. 
 
- The power cord must be plugged into approved bases. Be sure that it is properly grounded  
  before use. When unplugging it, hold the plug, not the wire.
 
-  Do not work on electrically live parts.
 
- The tool should be placed in the stand when not in use in order to activate the sleep mode.  
  The soldering tip, the metal part of the tool and the stand may still be hot even when the station is  
  turned off. Handle with care, including when adjusting the stand position.

- Do not leave the appliance unattended when it is on. 

- Do not cover the ventilation grills. Heat can cause inflamable products to ignite. 
 
- Use a “non residue” classified flux and avoid contact with skin or eyes to prevent irritation. 
 
- Be careful with the fumes produced when soldering.

- Keep your workplace clean and tidy. Wear appropriate protective glasses and gloves when  
  working to avoid personal harm. 

- Utmost care must be taken with liquid tin waste which can cause burns. 

- This appliance can be used by children over the age of eight and also persons with reduced 
  physical, sensory or mental capabilities or lack of experience provided that they have been given  
  adequate supervision or instruction concerning use of the appliance and understand the hazards  
  involved. Children must not play with the appliance. 

- Maintenance must not be carried out by children unless supervised.

www.jbctools.com

23

Содержание DMVE-1A

Страница 1: ...Premium 4 Tools Rework station with Pneumatic Pump Ref DMVE A www jbctools com...

Страница 2: ...Pneumatic Desoldering Module 1 unit Ref MVE A Tip Cleaner 1 unit Ref CL9885 Module Cable 1 unit Ref 0014874 DME Control Unit 1 unit Ref DME 1A 120V DME 2A 230V DME 9A 100V Union Flanges 1 unit Ref 00...

Страница 3: ...unit Ref 0965970 Filter Box 1 unit Ref 0780840 It contains 10 filters Spanner 1 unit Ref 0780550 Tin deposit 1 unit Ref 0812620 Long Tip Cleaning set 1 unit Ref 0965760 Metal tin diposit 1 unit Ref 0...

Страница 4: ...Ref AD SD General Purpose Handle Ref T245 A Desoldering Iron Ref DR560 A Cartridge Ref C245903 Ref C245906 Tip Ref C560004 Ref C560005 Ref C560013 Stand Ref DR SD Stand Cable Ref 0011283 RJ12 connect...

Страница 5: ...Ref MVE A To another peripheral To Pedal Ref P 005 USB A connector 3 5 Color TFT Touch screen Tilt the display for easy reading Suction Filter Ref 0821830 Module Cable Ref 0014874 Speaker Air pressur...

Страница 6: ...artridges without interrupting your work Adjustable tool holder Suits your work position Adjustable cable collector Adjustable Stands Stand Ref DR SD Quick tip changer Holding tip system for easy chan...

Страница 7: ...vent oxidation between cleaning and rewetting It prevents splashing of solder particles when using the brass wool Heavy weighted non slip base for simple handed cleaning The least harmful cleaning met...

Страница 8: ...s follows A For straight C210 B For curved C210 C For curved C245 D For straight C245 Important It is essential to insert the cartridges as far as the mark for a proper connection B C A D Compatible c...

Страница 9: ...max pin 0 6 C560 003 A 2 7 B 1 max pin 0 8 C560 004 A 3 2 B 1 3 max pin 1 1 C560 009 A 5 B 1 3 max pin 1 1 C560 014 A 2 5 B 0 8 max pin 0 6 1 Removing Unscrew the tip using the spanner supplied 2 Ins...

Страница 10: ...the screw as shown and remove the Heating Element 3 Placing Place the new Heating Element and follow the steps conversely 2 1 3 To perform this operation turn off the station or disconnect the tool Im...

Страница 11: ...d and replaced if dirty or damaged Remove the coil to clean the inside of the deposit with the stick supplied The lid must be removed with the DR560 in vertical position The deposit must be inserted w...

Страница 12: ...s are left on a terminal after desoldering it resolder it with fresh solder and repeat the desoldering operation When the solder liquefies gently rotate the tip so that the compo nent terminal can be...

Страница 13: ...the Peripherals Menu and select the port which you want to join with the module MVE Changing the pump filters Use a damp cloth to keep the casing clean Periodically check all cable and tube connection...

Страница 14: ...is lifted from the stand the tip will heat up to the selected temperature When the tool is in the stand the temperature falls to the preset Sleep temperature After longer periods of inactivity the po...

Страница 15: ...livered for each port Tool in use Press here to see the Ports Screen Cartridge in use Introduce the reference for more precise temperatures readings Station Lock PIN required for unlocking See the inf...

Страница 16: ...een Utilities Select any option and press the station information button to display each parameter description Useful additional applications that complement and support your work View your video via...

Страница 17: ...Indicates there is a peripheral to be installed After connecting the tool introduce the last 3 reference numbers of the cartridge Insert the cartridge model and the station will recognize its characte...

Страница 18: ...ch tip to use to obtain the best quality soldering Process analysis Export graphics Insert a USB flash drive into the USB A connector to save your soldering process in csv format Graphics Temperature...

Страница 19: ...specific configurations for later uses Analyze the soldering graphics of the stations on your PC and export them 1 Download the JBC Manager software and the user manual from www jbctools com manager...

Страница 20: ...nect the other PSE s as follows Centralize control of 3 PSE Power Supply Units in a single DME and work with as many as 16 tools simultaneously Increase x4 your DME s possibilities Four Tool Control U...

Страница 21: ...o the Robot Communication Protocol available on the website www jbctools com jbcsoftware menu 115 html Manage and monitor the station using a Robotic system Working with Robots Control Unit Robot Upda...

Страница 22: ...and remove the fuse If necessary use a tool to lever it off 2 Press the new fuse into the fuse holder and replace it in the station Use a damp cloth to clean the casing and the tool Alcohol can only b...

Страница 23: ...appliance unattended when it is on Do not cover the ventilation grills Heat can cause inflamable products to ignite Use a non residue classified flux and avoid contact with skin or eyes to prevent irr...

Страница 24: ...ol Temperature Range 90 450 C 190 840 F Idle Temp Stability still air 1 5 C 3 F Ambient Operating Temperature 10 40 C 50 104 F Tip to ground resistance 2 ohms Tip to ground voltage 2mV RMS USB A USB B...

Страница 25: ...www jbctools com 25...

Страница 26: ...Exploded View Despiece Explosionszeichnung 26...

Страница 27: ...www jbctools com 27...

Страница 28: ...roduct wear due to use or mis use In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased This product should not be thrown in the garbage In...

Отзывы: