manualshive.com logo in svg
background image

Clean periodically

Maintenance

Before carrying out maintenance or storage, always allow the equipment to cool. 

- Clean the station screen with a glass cleaner  

or a damp cloth.

1.

 Pull off the fuse holder and remove the  

 fuse. If necessary use a tool to lever it off.

2. 

Press the new fuse into the fuse holder  

  and replace it in the station.

- Use a damp cloth to clean the casing and the 

tool. Alcohol can only be used to clean the 
metal parts.

- Periodically check that the metal parts of the 

tool and stand are clean so that the station 
can detect the tool status.

- Maintain tip surface clean and tinned prior to 

storage in order to avoid tip oxidation. Rusty 
and dirty surfaces reduce heat transfer to the 
solder joint.

- Periodically check all cables and tubes.

- Replace a blown fuse as follows:

- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.

Fuse holder

Fuse holder

Fuse

www.jbctools.com

7

Содержание DDVE-2B

Страница 1: ...Premium Rework Station with Pneumatic Pump Ref DDVE B INSTRUCTION MANUAL www jbctools com...

Страница 2: ...L6217 Module Cable 1 unit Ref 0014874 DDE Control Unit 1 unit Ref DDE 1B 120V DDE 2B 230V DDE 9B 100V Brass Wool 1 unit Ref CL6210 Desoldering Iron 1 unit Ref DR560 A Stand 1 unit Ref DR SE Power cord...

Страница 3: ...Ref 0812630 Tips 3 units Ref C560005 x1 Ref C560013 x1 Ref C560004 x1 Tip cleaning set 1 unit Ref 0965970 Long Tip Cleaning set 1 unit Ref 0965760 Suction Filter 1 unit Ref 0821830 Cotton Filter 1 un...

Страница 4: ...simultaneously with up to 2 tools and join each station port with 1 module 1 pedal Peripherals Stand Ref AD SE RJ12 connector for Robot USB B connector Equipotential connection Power Socket Desolderin...

Страница 5: ...21830 Module Cable Ref 0014874 USB A connector 2 8 Color TFT screen Tilt the display for easy reading Air pressure 4 6 bar Pneumatic Desoldering Module Ref MVE A To another peripheral To Pedal Ref P 0...

Страница 6: ...l Unit Stand Tool Cartridge Range MSE A MVE A MNE A FSE A P 005 DDE C AD SE T210 A C210 T245 A C245 T470 A C245 DN SE T210 NA C210 T245 NA C245 T470 NA AP SE AP250 A C250 PA SE PA120 A C120 HT SE HT42...

Страница 7: ...ohol can only be used to clean the metal parts Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status Maintain tip surface clean and tin...

Страница 8: ...an cause inflamable products to ignite Avoid flux coming into contact with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear...

Страница 9: ...Pb Hg Cd Cr VI PBB PBDE O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O O O X O O O O O O GB T 26572 X GB T 26572 www jbctools com 9...

Страница 10: ...l Temperature Range 90 450 C 190 840 F Idle Temp Stability still air 1 5 C 3 F Tip to ground resistance 2 ohms Tip to ground voltage 2mV RMS Ambient Operating Temperature 10 40 C 50 104 F Communicatio...

Страница 11: ...Exploded View www jbctools com 11...

Страница 12: ...our website Warranty JBC s 2 year warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misu...

Отзывы:

Похожие инструкции для DDVE-2B