manualshive.com logo in svg
background image

www.jbctools.com

12

13

Before carrying out maintenance or storage, always allow the equipment to cool. 

- Clean the station screen with a glass cleaner 

or a damp cloth.

Remove the fuse by pulling the black cap.  
If necessary use a tool to lever it off.

Press the new fuse into the holder and 
replace it in the station.

Clean  
periodically

- Use a damp cloth to clean the casing and 

the tool. Alcohol can also be used when 
cleaning the metal parts.

- Periodically check that the metal parts of 

the tool/stand are clean so that the station 
can detect when the tool is in the stand. 

- Maintain tip surface clean and tinned prior 

to storage in order to avoid tip oxidation.  
Rusty and dirty surfaces reduce heat 
transfer to the solder joint.

- Periodically check all cables, tubes and        
   filters to ensure proper solder suction.

Maintenance

 

- Replace a blown fuse as follows:

- Replace any defective or damaged pieces. Use original JBC spare parts only. 

- Repairs should only be performed by a JBC authorized technical service.

  It is imperative to follow safety guidelines to prevent electric  
  shock, injury, fire or explosion. 

- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause 
fire. 
 
- The power cord must be plugged into approved bases. Be sure that it is properly grounded  
before use. When unplugging it, hold the plug, not the wire.
 
-  Do not work on electrically live parts. Antistatic handle of soldering irons is electrically 
conductive. 
 
- The tool should be placed in the stand when not in use in order to activate the sleep mode.  
The soldering tip, the metal part of the tool and the stand may still be hot even when the station is 
turned off. Handle with care, including when adjusting the stand position.

- Do not leave the appliance unattended when it is on. 

-  Do not cover the ventilation grills. Heat can cause inflamable products to ignite even when  
out of  sight. 
 
- Use a “non residue” classified flux and avoid contact with skin or eyes to prevent irritation. 
 
- Be careful with the fumes produced when soldering.

- Keep your workplace clean and tidy. Wear appropriate protective glasses and gloves when 
working to avoid personal harm. 

- Utmost care must be taken with liquid tin waste which can cause burns. 

- This appliance can be used by children over the age of eight and also persons with reduced 
physical, sensory or mental capabilities or lack of experience provided that they have been given 
adequate supervision or instruction concerning use of the appliance and understand the hazards 
involved. Children must not play with the appliance. Maintenance shall not be carried out by 
children unless supervised.

Safety

Содержание CSV-2D

Страница 1: ...English www jbctools com Compact Desoldering Station with Electric Pump Ref CS D...

Страница 2: ...ing Iron 1 unit Ref DS360 A Tips 5 units Ref C360002 Tips 5 units Ref C360004 Cleaning Rods Ref 0008466 Filter 2 units Ref 0008473 Cleaning brush Ref 0008297 Solder Collector 2 units Ref 0008467 DS360...

Страница 3: ...d Intelligent Heat Management Features Power Socket Main switch Equipotential connection Fuse USB B Micro Desoldering Iron Ref DS360 A Adjustable Stand Cable collector Adjust the tool stand to suit yo...

Страница 4: ...ations at the same time any JBC station USB Hub Cable USB AB JBC Updater www jbctools com 6 7 Tip Cleaning System Sponge Ref S0354 The least harmful cleaning method Keep the sponge damp with distilled...

Страница 5: ...tand after sleep No heat A c t u a l T e m p 2 0 o C Hibernation 0c Selected temp 350 o C P o w e r 1 0 350 3 Hibernation After long periods in the stand pre set 30 min the power is cut and the tool c...

Страница 6: ...sert the new heating element by following the same steps conversely Inside tip Pin C360 001 A 1 B 0 8 max pin 0 4 C360 007 A 1 9 B 1 4 max pin 1 2 C360 006 A 3 B 1 5 max pin 1 3 Changing the Tip Chang...

Страница 7: ...must be plugged into approved bases Be sure that it is properly grounded before use When unplugging it hold the plug not the wire Do not work on electrically live parts Antistatic handle of soldering...

Страница 8: ...145 mm Temperature selection 180 450 C 356 842 F Output Peak Power 40W Tip to ground resistance 2 ohms Ambient operating temp 10 40 C 50 104 F USB connector station PC MS A Weight 1 2 Kg 2 6lb Dimens...

Страница 9: ...roduct wear due to use or mis use In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased This product should not be thrown in the garbage In...

Отзывы: