Main menu
Main menu
4 Counters
5 Program version
Exit
1
Reset settings
2 Station settings
3
Tool settings
5 No tool hours 0
6 Sleep cycles 0
Tool 210
210
Back
Back
Back
Back
1
Fix one temp
-----
2 Temp levels set OFF
3
Sleep delay 0 min
5 Beep ON
6 QST ON
7 PIN ON
8 Change PIN
1
Temp unit
Celsius
2
Maximum temp 400
0
C
3 Minimum temp 200
0
C
4 Metronome ----
1
Plugged hours
0
2 Working hours 0
3
Sleep hours 0
4 Hibernation hours 0
Total Counters
Total Counters
Tool settings
Tool settings
Station settings
Station settings
0
Selected temp. 350
350
oo
C
C
P o w e r 5 %
P o w e r 5 %
Fixed temp.
350
350
oo
C
C
Levels
º
C 270
270 350
350 400
400
- 1 0
- 1 0
4 Sleep temp 150
0
C
5 Hibernation delay 10 min
6 Temp adjust + O
O
C
Tool 210
210
Back
Back
c
350
E A R T H
E A R T H
F U S E
F U S E
Station troubleshooting available on the product page at www.jbctools.com
Troubleshooting
Menu Screen
Default PIN: 0105
The work screen provides
useful information of tool
status in real time.
Work Screen
Control Process
Displays a specific fixed temp.
Shown when you have selected
temp. levels. The values must be
adjusted for the task.
“Temp. Adjust” parameter.
It provides a more precise
adjustment between the selected
temp and the actual one.
Earth Fuse warning is
shown when fuse is
blown. Replace the fuse.
Menu
Help Information
Station Settings
Minimum Temperature
Set the minimum temperature
to work with.
Min. temp. by default is 200ºC
(392ºF). This is considered to
be a proper starting point for
leaded applications.
Maximum Temperature
Set the maximum
temperature to work with.
Max. temp by default is 400°C
(750°F). This is considered
high enough to work with
most lead-free applications.
Temperature Unit
Celsius (ºC) or Fahrenheit (ºF)
Recommendations
Parameter Description
N/a
Warnings
The station temperature
range is 90-450ºC
(190-840ºF). Change the
temperature limits when
working with less common
applications such as low / high
melting point soldering (HMP)
or plastics (e. g. riveting).
In most cases,
working with temperatures
over 400°C (750°F) can
damage the PCB and its
components. Even in short
time periods of tip contact
with the soldering joint, the
flux may not work properly
and could seriously reduce
tip life. If the solder joint
requires more power
(e.g. multilayered or high
dissipation boards), JBC
strongly recommends using
other aids like preheaters.
Be careful when using these parameters as they may reduce the tip life if not used properly.
Please follow the recommended guidelines:
Parameters
Metronome
This activates a beep sound.
Frequencies vary from 1 to 50
seconds.
Change Pin
Change the default security
PIN number (0105).
The PIN must be entered every
time a parameter is changed.
Useful for setting a work rate
in repetitive jobs. The beep
lets you know the length of
time the tip must be in contact
with the soldering joint.
N/a
N/a
N/a
N/a
Pin
Enable/disable pin prompt.
N/a
N/a
QST
Enable/disable QST.
N/a
N/a
Beep
Enable/disable the beep
sound of the keypad.
14
Содержание CS-1F
Страница 1: ...INSTRUCTION MANUAL CDD Desoldering Station ...
Страница 21: ...Notes 21 40 mm 50 mm 60 mm 80 mm 100 mm 130 mm 130 mm para manuales color gris 200 mm ...