Hibernation Delay
Set the time the tool will re-
main at Sleep temperature be-
fore entering the Hibernation
mode. At this time, the power
supply is cut off and the tip
remains at room temperature.
Temp Adjustment
It provides a more precise
adjustment between the
selected temperature and the
actual one.
This function completely
protects the tip from oxida-
tion during long periods of
inactivity while the tool is in
the stand.
Retinning the tip before pla-
cing the tool in the stand also
helps prevent oxidation and
extends the life of the tip.
Set values within ±50°C
(± 90°F) to achieve zero error.
JBC strongly recommends the
use of TID-A or TIA-A Ther-
mometers to obtain precise
readings.
Tool Settings
Increasing the default
value will accelerate
oxidation and shorten the
tip life.
When the user changes
the cartridge type, the
parameter should be reset
to 0°C/F or to the value
needed for this cartrid-
ge. E.g. If a correction of
+20°C (+36°F) is set for the
C245966 (thick type) and
then the user changes the
cartridge for a C245030
(which is thinner) without
resetting, they would be
working at a temperature
of +20°C (+36°F) lower for
the C245030 which does
not need any temperature
adjustment.
Recommendations
Parameter description
Warnings
12
Содержание CP-1E
Страница 1: ...中文 48 Deutsch 32 Español 16 Compact Micro Tweezers Station Ref CP E English 2 Page www jbctools com ...
Страница 16: ...16 ...
Страница 17: ...Estación con Micro Pinza Ref CP E www jbctools com 17 ...
Страница 32: ...32 ...
Страница 33: ...Station mit Mikro Entlötpinzette Ref CP E www jbctools com 33 ...
Страница 49: ...电源插座 主开关 保险丝 电位连接 USB B 接口 产品特性 微型镊 Ref PA120 A 集线器 焊嘴清 洁系统 操作控制 可调式支架 智能热管理 www jbctools com 49 ...
Страница 62: ...Exploded View Despiece Explosionszeichnung 分解图 62 ...