manualshive.com logo in svg
background image

Main menu

4      Counters
5       Program version

      

  

Exit

1       

 Reset settings

2       Station settings

3

       Tool settings

4   Hibernation hours          0 
5    No tool hours                     0
6    Sleep cycles                       0

Tool 210

Back

Back

1      

Fix one temp    

            -----

2    Temp  levels  set          OFF

3

    Sleep delay                0   min

5    Help text                           OFF
6    Beep                                     ON
7    Change PIN                      

1    

Temp unit    

            Celsius

2

  Maximum temp   400

0

C

3  Minimum temp     200

0

C

4    Metronome                           ----

1   

 Plugged hours    

             0

2   Working hours                0

3

   Sleep hours                       0

Counters

Tool settings

Station settings

0

Selected temp.  350 

o

C

P o w e r   5 %

Fixed temp. 

 350

 

o

C

Levels 

º

C  270  

350 

 400

- 1 0

4   Sleep temp                   150

0

5     Hibernation delay       10   min
6   Temp adjust                + O  

O

C

Tool 210

Back

c

350

0

c

P o w e r   5 %

350

Selected temp  350 

o

C

S l e e p   t e m p   1 5 0

o

C

Sleep

0

c

350

Tool in the stand, no heat

Hibernation

0

c

350

Menu Screen

Original PIN: 0105

The work screen provides 
useful information of tool 
status in real time.

Work Screen

Control Process

Displays a specific fixed temp. 

Shown when you have selected 
temp. levels. The values must be 
adjusted for the task.

 
“Temp. Adjust” parameter. 
It provides a more precise 
adjustment between the selected 
temp and the actual one.

Operation

The JBC Exclusive Heating System

This revolutionary technology is able to recover tip temperature extremely quickly.
This allows the user to work at a lower temperature. 
As a result, tip life increases by 5.

· Change temperature  
  (from 90 to 450ºC) 
· Select temperature levels 
· Fix one temperature

· Change Sleep temperature  
· Set Sleep delay 
  (from 0 to 9 min or no Sleep)

· Change Hibernation delay  
  (from 0 to 35 min)

Long time in 
the stand

1. Work

2. Sleep

3. Hibernation 

When the tool is lifted from the 
stand the tip will heat up to the 
selected temperature. 

When the tool is in the stand, 
the temperature falls to the 
preset sleep temperature.

After longer periods of 
inactivity, the power is cut off 
and the tool cools down to 
room temperature.

www.jbctools.com

8

9

Содержание CD-SE

Страница 1: ...Precision Soldering Station Ref CD SE www jbctools com ...

Страница 2: ... units Ref C210001 x1 C210008 x1 Precision Purpose Handle 1 unit Ref T210 A Sponge 1 unit Ref S0354 Power Socket Main switch Fuse Cable collector Quick Tip Changer Process Screen Adjustable Stand Intelligent Heat Management Equipotential connection USB B connector Features Precision Purpose Handle Ref T210 A Tip Cleaner brass wool with antisplash membrane Precision Soldering Station Ref CD SE www ...

Страница 3: ...and to suit your work position Fix the cable on the collector so that the working area is free of cable Tip Cleaner Select the option to suit your needs and improve the thermal transfer of the tip Brass Wool Ref CL6210 Very effective cleaning method Leaves a small layer of solder on the tip preventing oxidation between cleaning and rewetting Splashguard Ref 0017576 When using the brass wool it pre...

Страница 4: ...traight C210 B For curved C210 C For C245 Important It is necessary to insert the cartridges as far as the mark for a proper connection Mark USB Connector Download the latest software from our website to update your soldering station JBC Updater www jbctools com software html Update the station software via USB connection Cable USB AB JBC Manager www jbctools com manager html Manage and monitor as...

Страница 5: ...tatus in real time Work Screen Control Process Displays a specific fixed temp Shown when you have selected temp levels The values must be adjusted for the task Temp Adjust parameter It provides a more precise adjustment between the selected temp and the actual one Operation The JBC Exclusive Heating System This revolutionary technology is able to recover tip temperature extremely quickly This allo...

Страница 6: ...aches when returned to the stand Station Settings Minimum temperature Set the minimum temperature to work with Min temp by default is 200ºC 392ºF This is consi dered to be a proper starting point for leaded applications Maximum temperature Set the maximum temperature to work with Max temp by default is 400 C 750 F This is considered high enough to work with most lead free applications Temperature ...

Страница 7: ...rature before entering the Hiber nation mode At this time the power supply is cut off and the tip remains at room temperature Recommendations Parameter description Warnings Increasing the default value will accelerate oxidation and shorten the tip life When the user chan ges the cartridge type the parameter should be reset to 0 C F or to the value needed for this cartridge E g If a correction of 2...

Страница 8: ...ppliance unattended when it is on Do not cover the ventilation grills Heat can cause inflamable products to ignite Avoid the contact of flux with skin or eyes to prevent irritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriate protection glasses and gloves when working to avoid personal harm Utmost care must be taken with liquid tin waste whi...

Страница 9: ...ent must be returned postage paid to the dealer where it was purchased Specifications CD 1SE 120V 50 60Hz Input fuse 2A Output 23 5V Control Unit model CD 1E CD 2SE 230V 50 60Hz Input fuse 1A Output 23 5V Control Unit model CD 2E CD 9SE 100V 50 60Hz Input fuse 2A Output 23 5V Control Unit model CD 9E Net Weight 2 86 Kg 31 lb Dimensions 150 x 175 x 145 mm Output Peak Power CD SE 40W Temperature Ran...

Отзывы: