Sleep Delay
Set the time that the tool
will remain at the selected
temperature when in the stand
before entering Sleep mode.
The tip temperature will then
drop to the Sleep temperature.
Fix One Temperature
Fix a value within the
temperature range of the
station (90-450 ºC/190-
840 ºF).
Temperature Levels Set
Similar to “Fix one temp”
parameter. In this case, the
user can set up to 3 values for
different power requirements.
Sleep temperatures are
set to achieve a balance
between preventing oxidation
and reaching the working
temperature in a few seconds.
Ideal for soldering more than
one component at a specific
temperature. The station will
reject any attempt to change
the temperature.
This allows a quick change
between 3 different tempe-
ratures. Set them according
to the allowed values for your
soldering applications.
Because our tools reach the
working temperature from the
deafult Sleep mode in only a
few seconds, this parameter is
preset to 0 min. Once the tool
is returned to the stand, the
temperature will automatically
drop to Sleep temperature,
extending tip life and avoiding
oxidation. Retinning the tip
before placing the tool in the
stand will protect the tip and
extend its life.
Recommendations
Parameter Description
Warnings
N/a
N/a
Setting these
parameters to higher values
will unnecessarily accelerate
oxidation and shorten tip
life especially when working
with temperatures up to
450 °C / 840 °F.
Tool Settings
Sleep Temperature
This is the set temperature the
tip reaches when returned to
the stand.
Hibernation Delay
Set the time the tool will
remain at Sleep Temperature
before entering in Hibernation
Mode. At this time, the power
supply is cut off and the tip
remains at room temperature.
Tool Settings
Recommendations
Parameter Description
Warnings
Increasing the default
value will accelerate
oxidation and shorten the
tip life.
When the user changes
the cartridge type, the
parameter should be reset
to 0 °C/F or to the value
needed for this cartridge.
E.g. If a correction of +20 °C
/ +36 °F is set for a thick
cartridge and then the
user changes to a thinner
one whitout resetting the
temperature adjustment, he
would be working at a higer
temperature than needed
for this thinner cartridge,
which does not need any
temperature adjustment.
This function completely
protects the tip from oxidation
during long periods of
inactivity while the tool is in the
stand.
Retinning the tip before
placing the tool in the stand
also helps prevent oxidation
and extends the life of the tip.
Temp Adjustment
It provides a more precise
adjustment between the
selected temperature and the
actual one.
Set values within ±50 °C
/ ± 90 °F to achieve zero error.
JBC strongly recommends
the use of TID-A or TIA-A
Thermometers to obtain
precise readings.
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm
130 mm
para manuales - color gris
200 mm
300 mm
14