manualshive.com logo in svg
background image

WARRANTY

JBC’s 2 years warranty guarantees this equipment against all manufacturing defects, covering the replacement of defective parts and 

all necessary labour. Warranty does not cover product wear due to use or mis-use.
In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased enclosing this 

fully completed form.

SERIAL Nº

DATE OF PURCHASE

STAMP OF DEALER

press SELECT key 2 

seconds to enter Menu

DEFAULT PIN: 0105

SELECT

CHANGE STATION
PARAMETERS            S

Language?
ENGLISH                      S

Tool Select
T245/T210                     S

Total Hours
                00000                  S

Temperature Unit

CELSIUS/FAHRENHEIT        

S

Fix Temp. Levels
              OFF/ON                 S

Work Hours
                00000                  S

Max. T= [400

o

C]               S

Min.   T=   200

o

C                

Sleep Dealy Time
           0 MINUTES              S

Sleep Hours
                00000                  S

Max. T=  400

o

C

Min.   T= [ 200

o

C]               S

           Power Limit
                   130W                  S

                 Popup
ENABLED/DISABLED   S

Sleep Temperat.
     220 

o

C/

o

F                     S

Hibern. Hours
                00000                  S

Change PIN

YES/NO

         Hibernation
         30 MINUTES             S

Sleep Cycles
                00000                  S

Temperat. Adjust
+/- 0  

o

C/

o

F                       S

Save Changes?
     NO                 YES

Save Changes?
     NO                 YES

CHANGE TOOL
PARAMETERS            S

COUNTERS READ

                                         S

RESET PARAMETERS
                                         S

EXIT SETUP

                                         S

MENU SETTINGS

0008802-0610

4

TECHNICAL SPECIFICATIONS

-  Temperature selection from 90 to 450°C (±5%).
-  Power: 75W.
-  Safety transformer, mains separator and double isolation, with temperature protection fuse.

BD-2BA / BD-2SA

 230V control unit. Input: 230V 50Hz. Output: 24V.

BD-1BA / BD-1SA

 120V control unit. Input: 120V 60Hz. Output: 24V.

-  Total weight of unit: 2,6 Kg.
-  Complies with CE standards on electrical safety, electromagnetic compatibility and ESD protected housing 

“skin effect”.

-  RoHS compliant.
-  Equipotential connector and the tool tip are connected to station mains ground supply for ESD protection.

This product should not be
thrown in the garbage.