![jbc B-iRON 210 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/jbc/b-iron-210/b-iron-210_instruction-manual_636827009.webp)
Replacing Brass Wool
1. Lifting
2. Replacing
Space
3. Assembling
4. Pressing on
Lift and remove the antisplash membrane.
Replace the brass wool with a new one. Make
sure that the brass wool is on the far left and that
there is space for the wiper on the right.
Assemble the antisplash membrane in vertical
direction onto the stand.
Press the antisplash membrane down. Make sure
that the membrane is correctly inserted all around.
Note:
The brass wool and the wiper position can be reversed by rotating the antisplash
membrane 180 degrees