background image

Replacing Brass Wool

1. Lifting

2. Replacing

Space

3. Assembling

4. Pressing on

Lift and remove the antisplash membrane.

Replace the brass wool with a new one. Make 
sure that the brass wool is on the far left and that 
there is space for the wiper on the right. 

Assemble the antisplash membrane in vertical 
direction onto the stand. 

Press the antisplash membrane down. Make sure 
that the membrane is correctly inserted all around. 

Note: 

The brass wool and the wiper position can be reversed by rotating the antisplash 

membrane 180 degrees

9

Содержание B-iRON 115

Страница 1: ...Nano B iRON Station B iRON 115 INSTRUCTION MANUAL ...

Страница 2: ...CL0300 already assembled in the stand B 115 Nano Tool 1 unit Ref B115 A This manual corresponds to the following references Console included BI115UA 120 V N America Taiwan BI115IA 230 V India BI115A 230 V Europe BI115KA 230 V United Kingdom BI115HA 230 V China BI115JA 100 V Japan Cable USB 1 unit Ref 0028092 B iRON Console 1 unit included according purchased reference Console not included BI115UQA...

Страница 3: ...rences without console blue tooth device like PC or mobile can be connected Power Socket USB Connector USB Cable only for charging Bluetooth Connection Stand for B 115 Nano Tool Screw to detach the Support Quick Tip Changer Brass Wool inside Cartridge Storage Antisplash Membrane Cartridge C115 Range not included 3 ...

Страница 4: ...the tool completely 30 min before using for the first time The status indicator light idicates as follows the tool status 2 1 Status Indicator Light 1 Connection 2 Cartridge Insertion and Charging green working soldering green blinking charging alternating red green blinking low battery less than 20 red blinking no cartridge no color power OFF 4 ...

Страница 5: ...Application Menu Connected Tool Temperature Selection Slider Tool Status Battery Level Tool Status The work screen shows the graph of the current tip temperature and the power supplied to the tip by moving the graph permantely to the left 3 Switching on Console Device Select the tool from the detection list Turn on the console device and open the B iRON Application 4 Selecting Tool Console Work Sc...

Страница 6: ...ation When the tool is lifted from the stand the tip will heat up to the selected temperature When the tool is in the stand enters into Hibernation Mode and cools down to room temperature While the tool remains in the stand it charges Hibernation When the tool is outside of the stand and remains inactive no movement the tool enters into Hibernation mode and cools down to room temperature To turn t...

Страница 7: ...rding is stopped you can get the temperature power value in a concret point by tapping the graph on the tablet screen When the tool ist not in use the grafics stops recording The grafic can be moved to the left and right by swiping the touch screen sideways with one finger The recording starts automatically as soon as the tool is removed from the stand and the graphic automatically jumps to the en...

Страница 8: ... for removing excess solder by gently tapping or wiping the cartridge tip If the tip is very dirty JBC recommends first cleaning it with the wiper to remove excess solder and than with the brass wool Brass Wool Ref CL0300 Very effective cleaning method Leaves a small layer of solder on the tip preventing oxidation between cleaning and rewetting Tap gently to remove excess solder Use the slots to r...

Страница 9: ... that the brass wool is on the far left and that there is space for the wiper on the right Assemble the antisplash membrane in vertical direction onto the stand Press the antisplash membrane down Make sure that the membrane is correctly inserted all around Note The brass wool and the wiper position can be reversed by rotating the antisplash membrane 180 degrees 9 ...

Страница 10: ... on top of the new cartridge and press down slightly Important Insert the cartridge until the metal ring comes to a stop The charging indicator light changes from red to green when the cartridge is proprely inserted Conical Chisel Conical Bent Bevel Compatible Cartridges B 115 Pecision Tool works with C115 Cartridges Find the model that best suits your soldering needs in www jbctools com until sto...

Страница 11: ...ion Tool Ref B210 A and for Nano Tool Ref B115 A soft foam grips Ref 0026437 are available Remove the prior grip and replace the grips easily using the slip on tabs To change the grips do as follows 1 Inserting Tabs 2 Inserting Handle 3 Removing Tabs Menu Settings The B iRON Console offers an intuitive user interface which provides quick access to station parameters Put the slide on tabs into the ...

Страница 12: ... starts when no movement ist detected Set sleep mode ON OFF The tip temperature will drop to the selected sleep temperature Allows selection of the maximum temperature that can be set for the work mode The tool status light indicates as follows the tool status Green working soldering Green blinking charching Alternating red green blinking low battery less than 20 Red blinking no cartridge No color...

Страница 13: ...ile from https www jbctools com jbcsoftware html Connect the console device via USB connection to the PC Ontheconsole devicenotificationbaratthetop open USBConnectionSettings andselect MTP On the PC copy the downloaded file to IT706 internal share storage JBC Once copying is finished disconnect the console device from the PC On the console device open the Application 1 and then select update 2 on ...

Страница 14: ...dically check that the metal parts of the tool and stand are clean so that the charging works properly Maintain tip surface clean and tinned prior to storage in order to avoid tip oxidation Rusty and dirty surfaces reduce heat transfer to the solder joint Do not use liquid such as alcohol thinner or benzene to clean the console Repairs should only be performed by a JBC authorized technical service...

Страница 15: ...nd gloves when working to avoid personal harm Utmost care must be taken with liquid tin waste which can cause burns This appliance can be used by children over the age of eight and also persons with reduced physical sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards i...

Страница 16: ...Notes 16 ...

Страница 17: ...Notes 17 ...

Страница 18: ...Notes 18 ...

Страница 19: ...Connections Bluetooth Low Energy BLE Ambient Operating Temp 10 50 C 50 122 F Tool Weight 30 g 0 07 lb With Console Total Net Weight 1437 g 3 17 lb Total Package Dimensions Weight 265 x 223 x 160 mm 1995 g L x W x H 10 43 x 8 78 x 6 30 in 4 40 lb Without Console Total Net Weight 973 g 2 15 lb Total Package Dimensions Weight 225 x 223 x 160 mm 1531g L x W x H 8 86 x 8 78 x 6 30 in 3 38 lb Complies w...

Страница 20: ... s 2 year warranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be valid equipment must be returned postage paid to the dealer where it was purchased Get 1 extra year JBC warranty by registering here https www jbctools com productregistration within 30 days...

Отзывы: