Safety

- Do not use the tool for any purpose other than soldering or rework. 

- The power cord must be plugged into approved bases. Be sure that it is properly grounded before 

use. When unplugging it, hold the plug, not the wire.

- The tool should be placed in the stand when not in use in order to activate the sleep mode. The 

soldering tip, the metal part of the tool and the stand may still be hot even when the station is turned 
off. Handle with care, including when adjusting the stand position.

- Avoid the contact of flux with skin or eyes to prevent irritation.

- Be careful with the fumes produced when soldering.

- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working 

to avoid personal harm.

- Utmost care must be taken with liquid tin waste which can cause burns.

- This appliance can be used by children over the age of eight and also persons with reduced physical, 

sensory or mental capabilities or lack of experience provided that they have been given adequate 
supervision or instruction concerning use of the appliance and understand the hazards involved. 
Children must not play with the appliance.

- Maintenance must not be carried out by children unless supervised.

It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion. 

40 mm

50 mm

60 mm

80 mm

100 mm

130 mm

130 mm

para manuales - color gris

200 mm

300 mm

Содержание AL250-B

Страница 1: ...AL250 Auto Feed Iron INSTRUCTION MANUAL...

Страница 2: ...0 Guide Tube 0 9 1 mm 0 035 0 04 in Ref 0002401 Manual 1 unit Ref 0012317 GAL0910 C250403 Packing List The following items are included This manual corresponds to the following reference AL250 B for A...

Страница 3: ...AL Auto Feed Soldering Station Stand Ref AL SF Power Socket Equipotential connection Pedal connection optional Auto Feed Iron Ref AL250 B Fuse Main switch Auto Feed Soldering Station not included 40 m...

Страница 4: ...E LOAD 1 key at the station till the solder wire comes out at the guide tube end 2 Fast Wire Dragging Adjust the dragging strength 1 to enable the solder wire to be passed on properly and to avoid any...

Страница 5: ...ng Loosen the cartridge screw 1 to release the cartridge 2 Place the cartridge in the extractor and pull the tool to remove the cartridge 3 C Inserting Changing Cartridges For a safe cartridge change...

Страница 6: ...on Ref AL250 B and Ref 0027332 Maintenance Clean periodically Before carrying out maintenance always unplug the stand and the tool Check periodically that the metal parts of the tool and the stand are...

Страница 7: ...uced when soldering Keep your workplace clean and tidy Wear appropriate protection glasses and gloves when working to avoid personal harm Utmost care must be taken with liquid tin waste which can caus...

Страница 8: ...electronic equipment at the end of its life must be collected and returned to an authorized recycling facility Warranty JBC s 2 year warranty covers this equipment against all manufacturing defects i...

Отзывы: