JB ELIMINATOR DV-6E-250SP Скачать руководство пользователя страница 4

4

JB INDUSTRIES 

 •  ELIMINATOR DC 6 CFM VACUUM PUMP OPERATING MANUAL  •  800 323 0811  •  SALES@JBIND COM  •  JBIND COM           

PART NO 10348-308   0523

                                                                              JB INDUSTRIES

WARRANTY

ELIMINATOR

®

 DC pumps are warrantied against defects in materials and workmanship for two years OTC— 

not changing oil will void warranty  
JB products are guaranteed when used in accordance with our guidelines and recommendations  Warranty 

is limited to the repair, replacement, or credit at invoice price, (our option) of products which in our opinion 

are defective due to workmanship and/or materials  In no case will we allow charges for labor, expense or 

consequential damage  Repairs performed on items out of warranty will be invoiced on a nominal basis; contact 

wholesaler for details  Product Warranty Registration, Limited Warranty and OTC Warranty are available online at 

www jbind com 

RETURN FOR REPAIR

In the event your pump requires repair, please contact JB Customer Service Department to obtain a  

Return Goods Authorization (RGA) number  Ensure that all returned products are packed to avoid any 

damage in shipment  Paperwork should be placed in a separate plastic bag and should include JB’s 

assigned RGA number, a description of the problem and any customer assigned repair or purchase  

order number, if applicable  

Contact Customer Service for RGA number: 

800 323 0811 Toll-free phone 

800 552 5593 Toll-free fax

Customers in Alaska, Arizona, California, Idaho, Montana, Nevada, Oregon, Utah, and Washington have the option of sending vacuum 

pump repairs to JB or Merced.

JB Industries

 

RGA#_________  

601 N  Farnsworth Ave  

Aurora, IL 60505 

630 851 9444 Tel 

630 851 9448 Fax

Merced AC Equipment Service

 

RGA#_________  

805 S  Fremont 

Alhambra, CA 91803 

626 293 5710 Tel 

626 289 1961 Fax 

TROUBLESHOOTING

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Pump hard to start

A  Power cord not plugged in securely 

B  Motor switch not on 

C  Pump temperature below 30°F 

D  Pump has not been shut down properly 

A  Plug power cord in securely 

B  Turn motor switch to ON position 

C  Warm up pump to 30°F and turn motor switch on 

D  Follow proper start up and shut down procedures

Pump won’t pull deep vacuum 

In order for your pump to pull to a near 

perfect vacuum, oil must be clean and 

moisture-free throughout evacuation  

A  Contaminated oil 

B  Oil level too low 

C  Air leak in system being evacuated 

D  Pump inlet fittings missing or not tightened 

E  Coupler slipping 

F  Missing or damaged seals or o-rings

A  Change oil 

B  Add oil 

C  Locate and repair leak(s) 

D  Clean or replace o-ring 

E  Tighten coupler set screws to flats of cartridge and motor 

F  Replace damaged seals or o-rings

Oil drips from point where 

shaft enters the pump housing

Damaged shaft seal

Replace shaft seal

Pump shuts down and will  

not start 

A  Thermal overload may be open 

A.  Step 1:

 Disconnect pump from system 

Step 2:

 Wait approximately 15 minutes for motor to cool 

Step 3:

 Turn pump on 

Step 4:

 If it cycles off again, return for repair

Pump cycles on and off from a 

completely cold start and then 

runs smoothly

A   Oil backed up into cartridge and was being 

cleared out

B  Pump has not been shutdown properly

Step 1:

 Remove 1/4" cap 

Step 2:

 Turn pump on

Motor just hums

If pump has been dropped, the armature in 

motor may be out of alignment with the motor’s 

bell housing

Step 1:

 Set pump on bench with motor standing up

Step 2:

 Loosen the four motor bolts

Step 3:

 Shake motor and re-tighten motor bolts

Step 4:

 Start pump

If this doesn’t work, the pump most likely will need to be sent in for repair 

Motor runs, but no suction

A  Flexible coupler is either broken or loose 

Step 1:

  Set pump on bench with motor standing up

Step 2:

  Look between motor and pump housing from the bottom to see if the flexible part of the coupler is split or broken  

If the coupler is not broken, the coupler may be spinning on either the shaft to motor or cartridge 

Step 3:

  Replace cartridge  Instructions at www jbind com - Support - User Manuals 

Содержание ELIMINATOR DV-6E-250SP

Страница 1: ...2 Pump Maintenance 2 Repair Parts 3 Troubleshooting 4 Return for Repair 4 Warranty 4 WARNING UNIT DRAINED OF OIL FOR SHIPMENT DO NOT OPERATE WITHOUT ADDING OIL OPERATING MANUAL 6 CFM ELIMINATOR DV 6EDC CFM 6 CFM MOTOR 1 2 HP DC VOLTAGE 115v 230v INTAKE PORT 1 4 x 3 8 OIL CAPACITY 25 oz WEIGHT 24 lb ...

Страница 2: ...ive you years of reliable service ELIMINATOR pumps are designed for deep vacuum work in air conditioning and refrigeration systems Adding Oil Step 1 Slowly add oil until level rises to the top of the oil level line Figure 1 Step 2 Replace oil fill plug If oil level is too low you will hear air out of the exhaust If oil level is too high excess oil will be blown out of the exhaust IMPORTANT Use oil...

Страница 3: ... NFT5 4 1 4 O ring cap 16 NFT5 6 3 8 O ring cap 17 PR 501 1 2 Rubber grip and cap 18 PR 22 Oil fill plug w o ring 19 PR 40 Stainless steel splash guard w screw 20 DV EP8 1 2 Red tethered safety exhaust cap 21 PR 205 3 8 Cushioned handle PR 65 1 2 Cushioned handle REF NO PART NO DESCRIPTION 1 PR 1 Sight glass 2 PR 2 Oil drain valve 3 PR 10 DV 3E DV 4E and DV 6E cover assembly w sight glass drain va...

Страница 4: ...r switch not on C Pump temperature below 30 F D Pump has not been shut down properly A Plug power cord in securely B Turn motor switch to ON position C Warm up pump to 30 F and turn motor switch on D Follow proper start up and shut down procedures Pump won t pull deep vacuum In order for your pump to pull to a near perfect vacuum oil must be clean and moisture free throughout evacuation A Contamin...

Отзывы: