ENGLISH
OPERATION MANUAL
JB SYSTEMS
®
3/38
LED CLUBSCAN
DESCRIPTION:
1. Hanging bracket with 2 knobs to fasten the unit and a mounting hole to fix a mounting hook.
2. DIP switches, used to set the DMX-starting address of the unit.
3. Optical lens with manual focus adjustment.
4. Scanning mirror.
5. Cooling system: used to cool the components inside the enclosure. Make sure to never cover this fan
outlet!
6.
¼” jack used to connect an optional CA-8 controller.
7. Din-5pin input, used to connect an optional wireless receiver, named RF-8R.
8. Microphone for the sound controlled functions
9. DMX input: 3pin male XLR-connector used to connect universal DMX-cables. This input receives
instructions from a DMX-controller or from another LED CLUBSCAN II light effect when used in
master/slave mode.
10. DMX output: 3pin female XLR-connector used to connect the LED CLUBSCAN II with the next unit in the
DMX chain or with another LED CLUBSCAN II when used in master/slave mode.
11. Mains input with IEC socket and integrated fuse holder, connect the supplied mains cable here.
12. Mains output with IEC socket: you can use a special IEC power cable to connect this output with the
mains input of the next Led ClubScan for easier linking.
OVERHEAD RIGGING
Important:
The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 20cm from surrounding walls.
The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
Before rigging make sure that the
installation area can hold a minimum point load of 10times the device’s
weight.
Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
Don’t cover any ventilation openings as this may result in overheating.